Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Supply Of 200 A 4 Pole Power Contractor For 750 V Ac As Well As 415 V Ac With Coil Voltage 415 V Ac Type Cal 16 11 A With Surge Suppressor Similar To Abb Model Ek 110 With Aux Contract 2 No 2 Nc Type Cal, 16 11 A As Per Bom Edts 103 Rev D
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106748419 |
|
Reference Number |
51246401B |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Jaipur |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092025/106748419/viewNitPdf_5081899.pdf |
| Start Date | August 18, 2025 20:03 |
| End Date |
Expired
11/09/2025
Expired 398 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
2 core x one and half sq mm pvc insulated copper conductor flexible pvc sheathed cable, 1100 volt,4 sq mm twin core aluminium cable,pvc insulated copper wire thrird fourth square mm , 1 core,copper wire one square mm single core, frlsh, 90mtr in roll,copper wire one and half square mm single core, frlsh, 90mtr in roll,copper wire two and half sq mm single core, frlsh, 90mtr in roll,11kv goab switch vertical type complete with all accessories suitable for 200amps.,11kv triple pole do fuse set,changeover switch 200a. 415v,switch fuse unit with enclosure, rating 200a,single pole mcb of b series 16 a,240 v, 50 hz, 10 ka,240 v, 32amp, singal pole with neutral spn, miniature circuit breaker mcb,240 v, 63amp, singal pole with neutralspn, miniature circuit breaker mcb,mccb 3p 415v 32a,mccb 32 a 4 pole 415 v,mccb 415v 63amp or mccb 63a, 3 pole,four pole mcb 63a, 415v,mccb 100 amp, three pole,mccb, 4 pole, 100a, 415v,mccb 150a,3 pole,mccb 200 amp, three pole,mccb, 4 pole, 200a, 415v,power point combined switch and sock
2 core x one and half sq mm pvc insulated copper conductor flexible pvc sheathed cable, 1100 volt,4 sq mm twin core aluminium cable,pvc insulated copper wire thrird fourth square mm , 1 core,copper wire one square mm single core, frlsh, 90mtr in roll,copper wire one and half square mm single core, frlsh, 90mtr in roll,copper wire two and half sq mm single core, frlsh, 90mtr in roll,11kv goab switch vertical type complete with all accessories suitable for 200amps.,11kv triple pole do fuse set,changeover switch 200a. 415v,switch fuse unit with enclosure, rating 200a,single pole mcb of b series 16 a,240 v, 50 hz, 10 ka,240 v, 32amp, singal pole with neutral spn, miniature circuit breaker mcb,240 v, 63amp, singal pole with neutralspn, miniature circuit breaker mcb,mccb 3p 415v 32a,mccb 32 a 4 pole 415 v,mccb 415v 63amp or mccb 63a, 3 pole,four pole mcb 63a, 415v,mccb 100 amp, three pole,mccb, 4 pole, 100a, 415v,mccb 150a,3 pole,mccb 200 amp, three pole,mccb, 4 pole, 200a, 415v,power point combined switch and sock
Read moreSupply of 200a 4 pole power contractor for 750 v ac as well as 415v ac with coil voltage 415v ac type cal 16-11a with surge suppressor similar to abb model-ek 110 with aux contract 2 no 2nc type cal, 16-11a as per bom edts 103rev d
For complete deion and other details, please refer to tender
Read moreBus bar 100a tpn 415v,bus bar 200a tpn 415v,aluminium thimbles lugs 16 sqmm,aluminium thimbles lugs
Read more
4 pole contactor for net 1 & 2, rated voltage : 1000v ac, rated kva : 100 at rated voltage & 70 deg. c and utilization category : 6a. aux. contact : 2no 2nc, control voltage : 415v ac with surge suppressor.
For complete deion and other details, please refer to tender
Read morePower contactor for lhb coaches with 2(nonc) & surge suppressor rating: 4 pole, 300a, 660v ac,coil voltage: 400-415. similar to abb part no. ek 210-40-11 model no. for contactor ek210 (sk825441) for coil: cat no. ar(sk826400ar) for no nc block: cal 16-11a (sk829002a). make - abb/ siemens or similar.
For complete deion and other details, please refer to tender
Read morePower contactor for lhb power cars rating 4 pole 300a, 660v ac, coil voltage 400 -415v ac similar to ek210-40-11, 415v, cal 16-11b rc-eh 300/415 sk825441-ar sk829002-b sk829007-b of make abb. for fitment in lhb power car power panel as per item page no.79, s.no.10 2&103 of specification edts-103,rev-d,am-7 or latest. make: abb, siemens
For complete deion and other details, please refer to tender
Read moreContactor for net 1 & net 2, rated volta [contactor for net 1 & net 2, rated voltage : 1000v ac, rated kva-100 at rated voltage & 70 degree centigrade and utilization category 6a. main pole :4, aux contact : 2no 2nc, control voltage: 415v ac /- 15 percent with surge suppressor, for lhb ac coaches . approved makes as per sr.no.3 of d common bom of rdso no.el/7.1.108/mssbc dt. 17.09.2021 conforming to spec no. rdso/pe/spec/ac/0184-2015 (rev.1) or latest will make and drawing/catologue
For complete deion and other details, please refer to tender
Read moreContactor for net 1 & net 2, rated volta [contactor for net 1 & net 2, rated voltage : 1000v ac, rated kva-100 at rated voltage & 70 degree centigrade and utilization category 6a. main pole :4, aux contact : 2no 2nc, control voltage: 415v ac /- 15 percent with surge suppressor, for lhb ac coaches . approved makes as per sr.no.3 of d common bom of rdso no.el/7.1.108/mssbc dt. 17.09.2021 conforming to spec no. rdso/pe/spec/ac/0184-2015 (rev.1) or latest will make and drawing/catologue
For complete deion and other details, please refer to tender
Read moreContactor 3 pole, 16 amp capacity suitable for 415v, 50 hz ac, coil voltage 110 dc with surge suppressor ( coil voltage range 77-137 v dc) with inc auxiliery contack block similar to abb code tal-16-30-01, rt 5/150 generally conforming to is- 13947 pt.- 4/1993.] accepted makes: abb, schneider, siemens.
For complete deion and other details, please refer to tender
Read morePower contactor 70 amps, 415 v, triple pole, with 2 no2nc aux contacts (side mounting), coil voltage 415v ac, confirming to is/iec 60947, part 4/sec 1. as per rcf specification no. edts-041, rev.-b. suitable for use in 200a battery charging unit of sg ac coaches. accepted make : siemens. abb, l&t. schneider only.
For complete deion and other details, please refer to tender