Tender Details
Particulars | Details |
---|---|
Title |
Supply Of Switch Disconnector Fuse Unit, Capacity 400 Amps, Three Pole With Neutral Link, Double Break, Front
Operated Handle With Sheet Steel Enclosure, As Per Is:13947[Pt1] 1993[Reaffirmed], Quick Make And Break, Interlock At
Cover,
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106429184 |
Reference Number |
97245838 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Chennai |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/082024/106429184/viewNitPdf_4665490.pdf |
Start Date | August 01, 2024 21:41 |
End Date |
13/08/2024 ( Expired 298 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Dust protecting totally enclosed, heavy duty double break fuse switch with hbc fuse links in sheet enclosure with standard cable entry holes and mounting arrangement suitable for utilization category ac-22a, 63 amps rating 415v ac,50 hz tpn [wp] conforming to is/iec-60947-1 and 3.
For complete deion and other details, please refer to tender
Read moreChange over switch with sheet steel enclosure double throw, quick make & break with interlocking arrangement and hinged door, conforming to is: 13947(pt.3)1993, utilization category ac-22, four pole, 415v, 100 amps.
For complete deion and other details, please refer to tender
Read moreProviding and fixing tpnn switch disconnector fuse unit with din fuse link in sheet steel enclosure used for secondary control of weighbridge, mtk and chp transformer.
Providing and fixing tpnn switch disconnector fuse unit with din fuse link in sheet steel enclosure used for secondary control of weighbridge, mtk and chp transformer.
Read moreDust protecting totally enclosed, heavy duty double break fuse switch with hbc fuse links in sheet enclosure with standard cable entry holes and mounting arrangement suitable for utilization category ac-22a, 63 amps rating 415v ac,50 hz tpn [wp] conforming to is/iec-60947-1 and 3.
For complete deion and other details, please refer to tender
Read moreSet of switch disconnecting fuse (sdf), 2 pole 315a, 415v insulation suitable for 690v with 315a, 415v, braking capacity of rated fuse - 100 ka (min) and metallic cover of approx. maximum size l=450mm, w=350mm & h=300mm with 02 nos of fuse (315a,415v)as per rdso modification sheet no. rdso/pe/ms/ac0086-2022 (rev.0), makes as per modification sheet no. l&t ck910070009 (switch disconnect or fuse with enclosure) & sf94234 (fuse), siemens 3kx8345-4ac (enclosure), 3kl8331-2uaoo (switch disconnect o
For complete deion and other details, please refer to tender
Read moreSupply of switch disconnector fuse unit, capacity125 amps, three pole with neutral link, double break, front operated handle with steel sheet enclosure, as per is:13947 [pt1]1993[reaffirmed], quick make and break, interlock at cover, uninterrupted duty as per utilization category ac-23a and confirming to is: 13947[pt.3]/1993 [reaffirmed-2004]. it shall be supplied with three numbers of bolted type hrc fuses having rupturing capacity not less than 80ka, confirming to is:13703/1993, suitable for
For complete deion and other details, please refer to tender
Read moreSupply of switch disconnector fuse unit, capacity 400 amps, three pole with neutral link, double break, front operated handle with sheet steel enclosure, as per is:13947[pt1] 1993[reaffirmed], quick make and break, interlock at cover,
For complete deion and other details, please refer to tender
Read moreSet of switch disconnecting fuse (sdf), 2 pole 315a, 415v insulation suitable for 690v with 315a, 415v, braking capacity of rated fuse - 100 ka (min) and metallic cover of approx. maximum size l=450mm, w=350mm & h=300mm with 02 nos of fuse (315a,415v)as per rdso modification sheet no. rdso/pe/ms/ac0086-2022 (rev.0), makes as per modification sheet no. l&t ck910070009 (switch disconnect or fuse with enclosure) & sf94234 (fuse), siemens 3kx8345-4ac (enclosure), 3kl8331-2uaoo (switch disconnect o
For complete deion and other details, please refer to tender
Read moreSwitch disconnector fuse unit, capacity [switch disconnector fuse unit, capacity 100 amps, three pole with neutral link, double break, front operated handle with ss sheet enclosure, as per is:13947[pt1] 1993 [reaffirmed], quick make and break, interlock at cover, uninterrupted duty as per utilization category ac-23a and confirming to is: 13947[pt3]/1993 [reaffirmed-2004]. it shall be supplied with three number bolted type hrs fuses having rupturing capacity not less than 80 ka, confirming to i
For complete deion and other details, please refer to tender
Read more250 amps 415 v four pole ac23 duty on lo [250 amps 415 v four pole ac23 duty on load euro change over switch with complete sheet steal enclosure, front handle operation i-o-ii, 50hz ,make-electra or similar ]
For complete deion and other details, please refer to tender
Read moreof your Industry type