Tender Details
Check your funding eligibility in 2 minutes.
Answer a few questions and our team will contact you with your best options.
Particulars | Details |
---|---|
Title |
3200 A 3 Pole Edo Do Acb W Oil And Release,Micro Switch For Common Indication,220 Vdc Shunt Trip Re
|
Description |
|
Organisation | COAL INDIA LIMITED | Ministry of Coal |
Tender Id | GEM/2024/B/5386472 |
Reference Number |
|
Tender Fee | |
EMD | |
Tender Value | |
Place | |
Link | https://bidplus.gem.gov.in/all-bids |
Start Date | September 27, 2024 23:11 |
End Date |
08/10/2024 ( Expired 263 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
S.No. | Seller Name | Offered Item | Participated On | MSE/MII Status | Status |
---|---|---|---|---|---|
1 | COMPEX SOLUTION | - | 08-10-2024 12:20:44 | MSE | Evaluated |
2 | Kesar Electric India | - | 23-10-2024 13:22:04 | N/A | Evaluated |
3 | SPARES 4U | - | 08-10-2024 11:52:33 | MSE | Evaluated |
4 | Spectrum Business Associates | - | 08-10-2024 15:16:51 | N/A | Evaluated |
5 | ZOYA ENTERPRISES | - | 08-10-2024 00:30:03 | N/A | Evaluated |
Micro limit switch, contact current rating: 10a 250v ac, contact config: 1nc, 1no, 1com, actuator: short roller lever and screws terminal, switch body size: 2.8 x 1 x 1.6cm / 1.1 x 0.39 x0.63 (l*w*h) fixing holes dia.: 0.32cm/0.13? for toilet indication lights (type h1) of lhb ac coaches as per vital electrocomp part no. vms-s-sr2-d3 type, acceptable make: calonix, vital, uxcell, omron or similar.
For complete deion and other details, please refer to tender
Read moreAir circuit breaker(acb) for dg set application of system , voltage-750 v , capacity-800 amp , breaking capacity - 50ka , frequency- 50 hz, 3 pole mf( with inbuilt uv protection , thermal , magnetic release and 6 no 6 nc aux contact block) similar to l&t make acb type : cn-cs 800c conforming to rcf specification no : edts 103 , rev-d , am-07 or latest, make- l&t, abb or equivalent in all respect. note: material should be supplied by oem or their authorized dealers only.
For complete deion and other details, please refer to tender
Read moreSupply and commissioning of air circuit breaker, type: aha08 (series) (manual draw out type), standard: iec 947-2 & is 13947-2, frequency: 50/60hz, pole: 04, current: 800 amp, ct ratio= 800:5, breaking capacity 50ka with adjustable overload, under voltage tripping with shunt trip and short circuit setting microprocessor based interlocked. (with panel busbar modification, aluminium short links-04 nos., insulated separators- 04 nos., fasteners and cable connection. make: control & switch gear.
For complete deion and other details, please refer to tender
Read moreMpcb for ventilation fan unit 1 & 2, thermal release range (rated current) : 2.5-4.0 a, class 10, breaking capacity : 50 ka, 3 pole, rated voltage 415 v ac, 1 no 1 nc auxiliary contact block as per rdso common bill of material letter no el/7.108/mssbc dated 17.09.21, make- abb catalogue no ms 116-4 / legrand / eaton / schneider catalogue no gv2me08gvae11/ l&t catalogue no st418960000/ siemens catalogue no 3rv2011 1ea103rv2901-1e only.
For complete deion and other details, please refer to tender
Read more3200a 3 pole edo do acb w- oil and release,micro switch for common indication,220 vdc shunt trip re
Read more
Suction pressure switch without cappilary for lhb type ac coaches ,range 30-60/22-58psips 27/45bar. ts30/85 degree centigrade ,6a 250 volt ac as per danfoss part no. acb-2 ua 439 w, 061f 7294/alco control ps3-af 3 hnspcn 0713228/sidwal part no. sr-075-1037a / intec part no.ic-075-1037.
For complete deion and other details, please refer to tender
Read morePower contactor [with diode] ,3 pole 16 amp cap 415 v ac, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, as per s.no. 147,and item no. k-14, of bill of material of rdso spec no. rdso/pe/spec/ac/0184-2015, rev-0,used for compressor motor circuit of lhb type ac coaches, confirming to rdso spec no. rdso / pe / spec / ac / 0184-2015 rev-0,suitable for lhb type ac coaches switch board cabinet [k-33].
For complete deion and other details, please refer to tender
Read moreMpcb for exhaust fan 1,2 and 3 wc mbs 25 auxiliary contact (1no1nc) and terminal block, rated current: 0.63 amp, thermal release range: 0.4- 0.63 a, rated voltage: 415 v ac, class-10, breaking capacity: 50 ka, pole-3p, cat no. ms116-0.63, hk1-11 of abb or gv2-me04gv-ae11 of schneider or 3rv2011-0ga10 3rv2901-1e of siemens or st41892oooo st41945oooo of l&t make. make- as per bom of lhb switch board cabinet specification no. rdso/pe/spec/ac/0192-2018 (rev-1) abb, schneider, siemens & l&t onl
For complete deion and other details, please refer to tender
Read moreProviding and fixing of 18 nos. earth leakage relay with cbct, test re switch ocb shunt trip coil in different vcb and ocb at main 11 kv/3.3 kv sub-station for protection and safety purpose under bhurkunda project under barka sayal area.
Providing and fixing of 18 nos. earth leakage relay with cbct, test re switch ocb shunt trip coil in different vcb and ocb at main 11 kv/3.3 kv sub-station for protection and safety purpose under bhurkunda project under barka sayal area.
Read moreof your Industry type