Repairing, Overhauling Installation Of Safety Device In 2 No. Ht Switches((A) 400 Amp,6.6 Kv Make Crompton Greaves Sl.No.17877 G(b) 400 Amp.6.6 Kv Vcb Switch
Description
For Repairing, Overhauling Installation Of Safety Device In 2 No. Ht Switches((A) 400 Amp,6.6 Kv Make Crompton Greaves Sl.No.17877 G(b) 400 Amp.6.6 Kv Vcb Switch Make Andrew Yule And Co. Ltd Sl.No.2842 Main Incoming 6.6 Kv At Mudidih 7 No. Substation Mdc
Organisation Bharat Coking Coal Limited | Public Sector Undertakings
Tender Id 2025_BCCL_341766_1
Reference
Number
GM/SA/AM(EnM)-NIT/2025-26/043
Tender Fee 0
EMD 2533
Tender Value -
Place MDC under Sijua Area
Link
View Original Tender Notice

https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=354285

Start Date August 20, 2025 22:30
End Date
Expired 29/08/2025

Expired 411 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro

Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro

Read more
Complete rewinding of 410kw, 550hp, 6.6kv, 1480rpm ht motor crompton greaves make sl.no.-tvc49051/3 of muraidih under amp colliery.

Complete rewinding of 410kw, 550hp, 6.6kv, 1480rpm ht motor crompton greaves make sl.no.-tvc49051/3 of muraidih under amp colliery.

Read more
Repairing of 6.6kv, 400amp andrew yule make flp vcb and 400 amp, 6.6kv mine line make vcb of khottadih colliery, pandaveswar area

Repairing of 6.6kv, 400amp andrew yule make flp vcb and 400 amp, 6.6kv mine line make vcb of khottadih colliery, pandaveswar area

Read more
Repairing of 6.6kv crompton greaves make 400amps ocb switch

Repairing of 6.6kv crompton greaves make&#x0d 400amps ocb switch sl no. 45832 controlling of&#x0d 1000 kva, 6.6kv/440v-550v transformer at&#x0d madhuban filter plant sub-station under, amp&#x0d colliery barora area

Read more
Repairing/ rewinding work of 1850kw, 6.6kv crompton greaves make ht motor of cw pumps stage-ii, stps, suratgarh

Repairing /rewinding work of 1850kw, 6.6kv crompton greaves make ht motor of cw pumps stage-ii, stps, suratgarh

Read more
Partial repairing of 11kv 400amp ocb switch crompton greaves make at ena ocp, kusunda area

Partial repairing of 11kv 400amp ocb switch crompton greaves make at ena ocp, kusunda area

Read more
Complete repairing/overhauling and installation of new safty device of ht ocb 6.6kv, 400a make crompton greaves sl no 27884g to act as primary controlling switch for 315kva, 6.6kv/440v transformer under gopalichak colliery.

Complete repairing/overhauling and installation of new safty device of ht ocb 6.6kv, 400a make crompton greaves sl no 27884g to act as primary controlling switch for 315kva, 6.6kv/440v transformer under gopalichak colliery.

Read more
Repairing of 6.6kv, 373kw make-crompton greaves induction motor required for hingula ocp.

Repairing of 6.6kv, 373kw make-crompton greaves induction motor required for hingula ocp.

Read more
11 kv spring charging motor suitable for crompton make vcb and 11 kv lever suitable for bhel/crompton greaves make vcb

11 kv spring charging motor suitable for crompton make vcb and 11 kv lever suitable for bhel/crompton greaves make vcb

Read more
Repairing of 6.6kv crompton greaves make 400amps ocb switch sl.no. 45832 controlling of 1000kva, 6.6kv/440v-550v transformer at madhuban filter plant sub-station under ampc barora area.

Repairing of 6.6kv crompton greaves make 400amps ocb switch sl.no. 45832 controlling of 1000kva, 6.6kv/440v-550v transformer at madhuban filter plant sub-station under ampc barora area.

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise