Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Supply Of 500k Va, 11k V/433 V Copper Wound Cast Resin Dry Type Indoor Transformer
|
| Description |
Supply Of 500k Va, 11k V/433 V Copper Wound Cast Resin Dry Type Indoor Transformer At 220k V Switchyard Moolamattom
|
| Organisation | Government of Kerala |
| Tender Id | 2023_KSEB_632523_1 |
|
Reference Number |
9/DYCE/23-24/SYD-Trfr/19.12.23 |
| Tender Fee | 5900 |
| EMD | 28900 |
| Tender Value | - |
| Place | Generation Circle Moolamattom |
| Link |
View Original Tender Notice
https://etenders.kerala.gov.in |
| Start Date | December 23, 2023 16:30 |
| End Date |
Expired
22/01/2024
Expired 996 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Supply of 01 no 1.250 mva 16.5/0.690 kv dyn11 dry type cast resin transformer for power house bhep-i
Supply of 01 no 1.250 mva 16.5/0.690 kv dyn11 dry type cast resin transformer for power house bhep-i
Read moreSupply of 01 no 630 kva 16.5/0.415 kv dyn11 dry type cast resin transformer for power house of bhep-i
Supply of 01 no 630 kva 16.5/0.415 kv dyn11 dry type cast resin transformer for power house of bhep-i
Read moreTggenco-ktps vii stage/paloncha - supply of lt resin cast current transformer,semiconductor fuses and terminal blocks
Tggenco-ktps vii stage/paloncha - supply of lt resin cast current transformer,semiconductor fuses and terminal blocks
Read moreOverhauling and maintenance of 500kva transformer 11kv/440v lighting transformer oil cooled type make gec s.no.vq87/3492 of patherdih township of patherdih coal washery
Overhauling and maintenance of 500kva transformer 11kv/440v lighting transformer oil cooled type make gec s.no.vq87/3492 of patherdih township of patherdih coal washery
Read moreRepairing of 160kw 3 phase induction motor, 30kw, 440v 3 phase induction motor and 11kv/440v, 500kva transformer of jrd siding of akkocp
Repairing of 160kw 3 phase induction motor, 30kw, 440v 3 phase induction motor and 11kv/440v, 500kva transformer of jrd siding of akkocp
Read moreInstallation, testing and commissioning of 500 kva, 11kv/433v transformer at township sub -station no.-1 and associated job for strengthening of lt network at the stps township under em-oph dept stps.
Installation, testing and commissioning of 500 kva, 11kv/433v transformer at township sub -station no.-1 and associated job for strengthening of lt network at the stps township under em-oph dept stps.
Read morePreventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Preventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Read moreRasin cast spout assy,spout filling with connector r y b,front insulated connector r phase,front insulated connector y phase phase,front insulated connector b phase,rear insulated connector r phase,rear insulated connector y phase,rear insulated connector b phase,instrument control box,vertical isolating trolley,earth leakage relay with cbct,power converter 110 v ac to 110 v dc,tripping coil,mechanism for tripping coil,master trip relay,epoxy resin cast potential transformer 11 kv 110v,digital protection relay,epoxy resin cast current transformer,side cable box
Rasin cast spout assy,spout filling with connector r y b,front insulated connector r phase,front insulated connector y phase phase,front insulated connector b phase,rear insulated connector r phase,rear insulated connector y phase,rear insulated connector b phase,instrument control box,vertical isolating trolley,earth leakage relay with cbct,power converter 110 v ac to 110 v dc,tripping coil,mechanism for tripping coil,master trip relay,epoxy resin cast potential transformer 11 kv 110v,digital protection relay,epoxy resin cast current transformer,side cable box
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreof your Industry type