Tender Details

About Tender

🚂 Procurement Opportunity: Ac Cab Fan Single Phase 🌬️ The Ministry Of Railways, Specifically The Central Government Ministry/Department, Is Issuing A Call For Tenders For The Supply Of Ac Cab Fan Single Phase 110 Volts, With A Power Rating Of 22.5 Percent, 50 Hz. The Fans Must Have A Black Enameled Painted Body And Base, With Copper Oxidized Blades Complying With The Specifications Of Clw/Es/F 4 Alt G Or The Latest Version. 📅 Bid Submission Deadline: April 18, 2024, 12:30 Pm Interested Vendors Should Refer To The Tender Document For Complete Details And Specifications. Submission Of Bids Is Free Of Cost, With No Tender Fee Or Earnest Money Deposit Required. Keywords: Ac Cab Fan, Single Phase, 110 Volts, Ministry Of Railways, Central Government, Tender, Procurement, Jabalpur
Particulars Details
Title
Ac Cab Fan Single Phase 110 Volts / 22.5 Percent , 50 Hz. Fan Body And Base Painted In Black Enamelled Paint & Guard, Blade In Copper Oxidised To Clw Specn No. Clw/Es/F 4 Alt G Or Latest.
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106288943
Reference
Number
20232810
Tender Fee 0
EMD 0
Tender Value -
Place Jabalpur
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/042024/106288943/viewNitPdf_4509721.pdf

Start Date March 13, 2024 19:03
End Date
Expired 18/04/2024

Expired 910 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Cab. heater 415 v +/- 22.5 percent , 50 cycle with fixing arrangment to clw specs no. clw/es/h1/e or latest.

Cab. heater 415 v +/- 22.5 percent , 50 cycle with fixing arrangment to clw specs no. clw/es/h1/e or latest.

Read more
Voltmeter for traction motor u1 & u2 as per spec. no. clw/es/i-21 alt a and with 110 volts ledillumination for wap4 & wag7 locomotives

Voltmeter for traction motor u1 & u2 as per spec. no. clw/es/i-21 alt a and with 110 volts ledillumination for wap4 & wag7 locomotives

Read more
Rotary switch for cab heater/cab fan as per clw specification.no. clw/es/3/0108 alt.a.

Rotary switch for cab heater/cab fan as per clw specification.no. clw/es/3/0108 alt.a.

Read more
Green indication lamp,110 v ac/dc, 20 ma as per clw spec no. clw/es/3/0072

Green indication lamp,110 v ac/dc, 20 ma as per clw spec no. clw/es/3/0072

Read more
Crew fan for wag-9 loco as per clw spec. no. clw/es/3/0110 alt. e.

Crew fan for wag-9 loco as per clw spec. no. clw/es/3/0110 alt. e.

Read more
Earth fault relay for aux. convertor 415/110v ckt. harmonic filter & control circuit (pos no. 89.2.89.5. 89.6 and 89.7) 150 ma 43 ohm-36/110 volt as per abb document no. hbvw400011r0001 or and clw spec. no. clw/es/3/0090, alt.-2

Earth fault relay for aux. convertor 415/110v ckt. harmonic filter & control circuit (pos no. 89.2.89.5. 89.6 and 89.7) 150 ma 43 ohm-36/110 volt as per abb document no. hbvw400011r0001 or and clw spec. no. clw/es/3/0090, alt.-2

Read more
Motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.

Motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.

Read more
Terminal block assly. having 8mm or 5mm stud with separate dmc 110 specification/drg. :- confirming to clw drg. clw/es/t- 26/f with latest alt. each no.consisting ref:a = 1 no., ref. h =1 no., ref. i = 4 nos., ref.j =4 nos. ref. k =2 nos. ref l =2 nos.

Terminal block assly. having 8mm or 5mm stud with separate dmc 110 specification/drg. :- confirming to clw drg. clw/es/t- 26/f with latest alt. each no.consisting ref:a = 1 no., ref. h =1 no., ref. i = 4 nos., ref.j =4 nos. ref. k =2 nos. ref l =2 nos.

Read more
Contactor for compressor & scavanger blower motor (pos no. 52.4, 47.2) type - lp1-d8011 fw, 80/125a - 750v - 3pole - 110 volt dc. as per specn. as per abb document no. - hbtg 585683r2927 or latest and clw spec no. clw/es/3/0095/d or latest note: latest alteration / specification will be applicable at the time of tender closing.

Contactor for compressor & scavanger blower motor (pos no. 52.4, 47.2) type - lp1-d8011 fw, 80/125a - 750v - 3pole - 110 volt dc. as per specn. as per abb document no. - hbtg 585683r2927 or latest and clw spec no. clw/es/3/0095/d or latest note: latest alteration / specification will be applicable at the time of tender closing.

Read more
Parts of led for conversion of 110 v dc 4 feet tube light fitting as per drawing no- clw/es/3/sk-1/0041 into 17 watt led light (+/- 10 percent tolerance) for replacement in the existing tube fixture in 3 phase electric locomotive, retrofittable in the existing tube fixture design as per above specification number without any alteration in mounting arrangement of loco. make- ki kumar/imw/light smith/philips/havells or similar

Parts of led for conversion of 110 v dc 4 feet tube light fitting as per drawing no- clw/es/3/sk-1/0041 into 17 watt led light (+/- 10 percent tolerance) for replacement in the existing tube fixture in 3 phase electric locomotive, retrofittable in the existing tube fixture design as per above specification number without any alteration in mounting arrangement of loco. make- ki kumar/imw/light smith/philips/havells or similar

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise