Supply And Delivery Of Mandatory Electrical And Mechanical Major Spare Compnents For Day To Day Operation And Maintenance Of 6.6 Kv/3 Mw Raw Water Pumping Stations, 220/6.6 Kv Substation Yards At Murmur And Bommakal Under Td Iv, Control Room
|
| Description |
Supply And Delivery Of Mandatory Electrical And Mechanical Spare Components For Day To Day Operation And Maintenance Of 6.6 Kv/3 Mw Raw Water Pumping Stations, 220/6.6 Kv Substation Yards At Murmur And Bommakal Under Sd Iv(electrical), Transmission Division.Iv, Control Room.
|
| Organisation | Information Technology Electronics and Communication Department Telangana | State Govt. and UT |
| Tender Id | 603642 |
|
Reference Number |
EP.No.38/CGM(E)/TC/T3/TD-IV/2025-26 dt:05.06.2025 |
| Tender Fee | 6674 |
| EMD | 1.89 Lakh |
| Tender Value | - |
| Place | TS |
| Link |
View Original Tender Notice
http://eprocurement.telangana.gov.in/ |
| Start Date | June 06, 2025 18:45 |
| End Date |
Expired
13/06/2025
Expired 467 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Supply and delivery of major electrical and mechanical major spare compnents for day to day prive operation and maintenance of 6.6kv/3mw clear water pumping stations, 220/6.6kv substation yeards at kondapa td-iv control room
Supply and delivery of major electrical and mechanical spare components for day to day prive operation and maintenance of 6.6kv/3mw clear water pumping stations, 220/6.6kv substation yards at kondapaka under eam cell, transmission division.iv, control room
Read moreSupply and delivery of major electrical and mechanical major spare components for day to day prive operation and maintennace of 6.6kv/3mw clear water pumping stations, 220/6.6kv substation yards at mallaram under eam cell, td-iv, control room
Supply and delivery of major electrical and mechanical spare components for day to day prive operation and maintenance of 6.6kv/3mw clear water pumping stations, 220/6.6kv substation yards at mallaram under eam cell, transmission division.iv, control room
Read moreSupply and delivery of various spares for 220/6.6kv substation, 3000kw/6.6kv vertical and hsc pumpsets like impeller, shaft sleeves, 6.6kv capacitors and de nde bearings etc., for raw water pumping stations at murmur and bommakal under gdwss ph-i under sd-iv(electrical), td-iv, control room.
Supply and delivery of various mandatory spares for 220/6.6kv substation, 3000kw/6.6 kv vertical and hsc pump sets like impellers, shaft sleeves, 6.6kv capacitors, and de nde bearings etc,. for raw pumping stations at murmur and bommakal under godavari drinking water supply scheme, phase-i under sd-iv(electrical), transmission division -iv, control room, secunderabad.
Read moreSupply and delivery of various mandatory spares for 3000kw/6.6kv vertical pumpsets like shaft impellers and sleeves etc., for raw wpumping station at murmur under gdwss, ph-i under sd-iv(electrical), td-iv, control room
Supply and delivery of various mandatory spares for 3000kw/6.6kv vertical pump sets like shaft impellers and sleeves etc., for raw pumping station at murmur under gdwss, ph-i under sd-iv(electrical), transmission division.iv, control room
Read moreSupply and delivery of electrical and mechanical major spare components for day to day prive operation and maintenance of 6.6kv/3mw clear water pumping station at mallaram and kondapaka under td-iv
Supply and delivery of electrical and mechanical major spare components for day to day prive operation and maintenance of 6.6kv/3mw clear water pumping stations, 220/6.6kv substation yards at mallaram and kondapaka under eam cell, transmission division.iv, control room
Read moreSupply, delivery and fixing of 900mm dua butterfly valve, 900mm dia non slam nozzle check valves (nrv) and 1200/1100mm dia bf valves for 3000kw/4021hp pumpsets at 6.6kv pumping station murmur, bommakal, mallaram and kondapaka under electrical sub division td-iv, control room
Supply, delivery and fixing of 900mm dia butterfly valves, 900mm dia non slam type nozzle check valves (nrv) and 1200/1100mm dia butterfly valves for 3000kw/4021hp pumpsets at 6.6kv pumping stations mumur, bommakal, mallaram and kondapaka under electrical sub division trans.div.iv, control room
Read moreN,s,d,e, t and comm of di, double flanged non slam type nozzle check valves and butterfly valves etc complete for 6.6kv pumping station at murmur, bommakal and mallaram under gdwss phase-i, om div.no.xxi
Manufacture, supply, delivery, erection, testing and commissioning of di, double flanged non slam type nozzle check valves and butterfly valves etc complete for 6.6kv, pumping station at murmur, bommakal and mallaram under godavari drinking water supply scheme, phase-i under gm(e), om div.no.xxi, control room.
Read moreRefurbishment and upgradation of existing old system including supply, delivery, erection, testing and commissioning of 3.3kv 503.0 kw, ht motors and mandatory spares for 3.3kv hsc pump sets at rajampet patancheru 6.6kv hsc pumpsets at phase-ii, iii and iv at kalabgoor, peddapur campus and 6.6kv vertical pump sets at intake well, kalabgoor under td-ii, patancheru
Refurbishment and up-gradation of existing old system including supply,delivery,erection,testing and commissioning of 3.3 kv 503.0 kw, ht motors and mandatory spares for 3.3 kv hsc pump sets at rajampet patancheru, 6.6 kv hsc pump sets at phase-ii,iii and iv of kalabgoor,peddapur campus and 6.6kv vertical pump sets at intake well, kalabgoor etc., under manjira drinking water supply scheme of transmission division no.ii, patancheru
Read moreRefurbishment of 2000kva rated,11kv/6.6 transformer and pumping station equipment duly repairing, reconditioning and replacement of spares to the 6.6kv ht panels also to provide mandatory spares the intake well raw water pumping station in kalabgoor under mwss phase i and phase ii under transmission division no.ii patancheru
Refurbishment of 2000kva rated, 11kv/6.6 transformer and pumping station equipment duly repairing, reconditioning and replacement of spares to the 6.6kv ht panels also to provide mandatory spares to the intake well raw water pumping station at kalabgoor under mwss phase-i and ii under transmission division no.ii, patancheru
Read moreRefurbishment of 2000kva rated,11kv/6.6 transformer and pumping station equipment duly repairing, reconditioning and replacement of spares to the 6.6kv ht panels also to provide mandatory spares the intake well raw water pumping station in kalabgoor under mwss phase i and phase ii under transmission division no.ii patancheru
Refurbishment of 2000kva rated, 11kv/6.6 transformer and pumping station equipment duly repairing, reconditioning and replacement of spares to the 6.6kv ht panels also to provide mandatory spares to the intake well raw water pumping station at kalabgoor under mwss phase-i and ii under transmission division no.ii, patancheru