Tender Details
| Particulars | Details |
|---|---|
| Title |
Power Contactor 4 Pole 200 Amp,750 Vac,Coil Voltage 415 Vac,2 No 2 Nc Aux.Contacts,With Surge Suppressor,As Per Serial No 57,And Item No K 01,
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106388468 |
|
Reference Number |
95245500 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Mumbai CST |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/102024/106489864/viewNitPdf_4733883.pdf |
| Start Date | October 04, 2024 23:17 |
| End Date |
Expired
17/10/2024
Expired 734 days ago |
Bidding on tenders like this?
Partners, bid preparation, supplier quotes and GeM registration, from our team and partners.
Power contactor in open execution with auxillary contact 2no 2nc, 3 phase, 415 volts, 110 amps capa,power contactor siemens make ac3 duty 3 tf 33 00-0amo-llkw. coil voltage, 220 vac 50 hz, 1 no 1 nc,power contactor 70 amps rated current at 440 vac, coil voltage 220-250 volts ac with 2no 2nc auxilar
Power contactor in open execution with auxillary contact 2no 2nc, 3 phase, 415 volts, 110 amps capa,power contactor siemens make ac3 duty 3 tf 33 00-0amo-llkw. coil voltage, 220 vac 50 hz, 1 no 1 nc,power contactor 70 amps rated current at 440 vac, coil voltage 220-250 volts ac with 2no 2nc auxilar
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Read moreHog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches
Hog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches
Read moreFeeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Read moreWorking and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Working and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Read morePower contactor 4 pole 200amp,1000 vac,coil voltage 415 vac,2no 2nc aux.contacts
For complete deion and other details, please refer to tender
Read morePower contactor 4 pole 200amp,750 vac,coil voltage 415 vac,2no 2nc aux.contacts,with surge suppressor,as per serial no 57,and item no k-01,of bill of material of rdso spec no rdso/pe/spec/ac/0184-2015 used for feeder contactor net 1,net 2,and confirming to rdso spec no rdso/pe/spec/ac/ 0184 -2015 rev.0,suitable for lhb type ac coaches switchboard cabinet [k-01] specn: rdso/pe/spec/ac/0184-2015
For complete deion and other details, please refer to tender
Read morePower contactor 4 pole 200amp,750 vac,coil voltage 415 vac,2no 2nc aux.contacts,with surge suppressor,as per serial no 57,and item no k-01,of bill of material of rdso spec no rdso/pe/spec/ac/0184-2015 used for feeder contactor net 1,net 2,and confirming to rdso spec no rdso/pe/spec/ac/ 0184 -2015 rev.0,suitable for lhb type ac coaches switchboard cabinet [k-01] specn: rdso/pe/spec/ac/0184-2015
For complete deion and other details, please refer to tender
Read moreThis tender has closed