Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
For The Work Of Break Down For Replacement Of Burnt And Damaged Vacuum Interrupters And Complete Repairing And General Over Hauling Of 11 Kv Vcb At Installed Various 33/11 Kv Sub Stations Under Eudd I, Meerut.
|
| Description |
For The Work Of Break Down For Replacement Of Burnt And Damaged Vacuum Interrupters And Complete Repairing And General Over Hauling Of 11 Kv Vcb At Installed Various 33/11 Kv Sub Stations Under Eudd I, Meerut.
|
| Organisation | Government of Uttar Pradesh |
| Tender Id | 2023_PVVNL_863088_1 |
|
Reference Number |
E-Tender No.-189/EUDC/MEERUT/2023-2024 |
| Tender Fee | 1180 |
| EMD | 2000 |
| Tender Value | - |
| Place | SE EUDC MEERUT |
| Link |
View Original Tender Notice
https://etender.up.nic.in |
| Start Date | November 20, 2023 14:30 |
| End Date |
Expired
25/11/2023
Expired 1055 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repairing and overhauling of 11 kv vcb/control panel work under eudd 33 kv stadium
Repairing and overhauling of 11 kv vcb/control panel work under eudd 33 kv stadium
Read moreRepairing and overhauling of 11 kv vcb/control panel work under eudd 33 kv expressway
Repairing and overhauling of 11 kv vcb/control panel work under eudd 33 kv expressway
Read moreRepairing and overhauling of 33 kv vcb/control panel work under eudd 33 kv expressway
Repairing and overhauling of 33 kv vcb/control panel work under eudd 33 kv expressway
Read moreFor the work of deducting and repairing the fault of damaged 11 kv underground cables under 11 kv operation and maintenance the area of eudd-11 kv and lt line-north, meerut.
For the work of deducting and repairing the fault of damaged 11 kv underground cables under 11 kv operation and maintenance the area of eudd-11 kv and lt line-north, meerut.
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreFor the work of replacement of burnt, damaged vacuum interrupters, complete repairing and general over hauling of 11 kv vcb at installed various 33/11 kv sub-stations under electricity urban distribution division-v, meerut.
For the work of replacement of burnt, damaged vacuum interrupters, complete repairing and general over hauling of 11 kv vcb at installed various 33/11 kv sub-stations under electricity urban distribution division-v, meerut.
Read moreE-tender enquiry for supply of 11 kv vacuum interrupters for vcb make areva (10 nos.) and , supply of 11 kv vacuum interrupters for vcb make rrispat (10 nos.)
E-tender enquiry for supply of 11 kv vacuum interrupters for vcb make areva (10 nos.) and , supply of 11 kv vacuum interrupters for vcb make rrispat (10 nos.)
Read moreE-tender enquiry for supply of 11 kv vacuum interrupters for vcb make areva (10 nos.) and , supply of 11 kv vacuum interrupters for vcb make rrispat (10 nos.)
E-tender enquiry for supply of 11 kv vacuum interrupters for vcb make areva (10 nos.) and , supply of 11 kv vacuum interrupters for vcb make rrispat (10 nos.)
Read moreof your Industry type