| Particulars | Details |
|---|---|
| Title |
Supply And Fittingof Buchholz Relay,Winding Temperature And Oil Temperature Projection Relaysto Give Alarm And Tripping Indications Of 2.5 Mva, 11 Kv 6.6kv/3.3 Kv M And B Switch Gears Ltd Make Transformer Having Sl.No Prm 210482 Installed At Surface11 Kv/6
|
| Description |
Supply And Fittingof Buchholz Relay,Winding Temperature And Oil Temperature Projection Relaysto Give Alarm And Tripping Indications Of 2.5 Mva, 11 Kv 6.6kv/3.3 Kv M And B Switch Gears Ltd Make Transformer Having Sl.No Prm 210482 Installed At Surface11 Kv/6
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2025_BCCL_335294_1 |
|
Reference Number |
BCCL/EJA/ENM/E Tender/2025-26/05 |
| Tender Fee | 0 |
| EMD | 5468 |
| Tender Value | |
| Place | E. J. Area, Bhowra |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=347581 |
| Start Date | May 12, 2025 23:30 |
| End Date |
Expired
19/05/2025
Expired 413 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Supply and installation of winding temperature meter, oil temperature meter and buchholz relay alam bell system in 02 nos of 1 mva,11kv/3.3kv,power transformers,installed at dumerbera sub-station of ara colliery under kuju area.
Supply and installation of winding temperature meter, oil temperature meter and buchholz relay alam bell system in 02 nos of 1 mva,11kv/3.3kv,power transformers,installed at dumerbera sub-station of ara colliery under kuju area.
Read moreProviding and fixing a safety device like buchholz relay, oil, and winding temperature meter and connecting with tripping device to both 3mva, 11kv/3.3kv power transformer i.) make- g.e.c., amp. 157.6/525.5, 3 phase, 50hz., sl. no. ct4368/b-24065 and
Providing and fixing a safety device like buchholz relay, oil, and winding temperature meter and connecting with tripping device to both 3mva, 11kv/3.3kv power transformer i.) make- g.e.c., amp. 157.6/525.5, 3 phase, 50hz., sl. no. ct4368/b-24065 and
Read moreOverhauling and oil filteration of power transformer of 2.5mva 11kv 3.3kv sl. no rpm 126 make m and b switch gear pvt. ltd. of 4a patch of bhowra south colliery.
Overhauling and oil filteration of power transformer of 2.5mva 11kv 3.3kv sl. no rpm 126 make m and b switch gear pvt. ltd. of 4a patch of bhowra south colliery.
Read moreRepairing of oil temperature and winding temperature indicator and mercury switch buchholz relay of 2.5mva and 1mva power transformer along with wiring of control circuit from transformer to control panel at ilbl ocp, lakhanpur area, mcl
Repairing of oil temperature and winding temperature indicator and mercury switch buchholz relay of 2.5mva and 1mva power transformer along with wiring of control circuit from transformer to control panel at ilbl ocp, lakhanpur area, mcl
Read moreSupply and installation of oil and winding temperature indicator with the trip/ alarm circuit of primary control switch with repairing of buchholz relay of 04 nos of transformer of khottadih colliery
Supply and installation of oil and winding temperature indicator with the trip/ alarm circuit of primary control switch with repairing of buchholz relay of 04 nos of transformer of khottadih colliery
Read more((a)rewinding and repairing of p.t. 11kv/110v and 6.6kv/110v 3phase and 3.3kv/110v 1phase 05nos.(b)repairing of 3.3kv/440v gec make switch sl.no.-m/406 (c)repairing of 1200a lt ocb switch gec make,type k-5, 440v,sl.no.50/0254 of muraidih, ampc.
(a)rewinding and repairing of p.t. 11kv/110v and 6.6kv/110v 3phase and 3.3kv/110v 1phase 05nos.(b)repairing 
 of 3.3kv/440v gec make switch sl.no.-m/406 (c)repairing of 1200a lt ocb switch gec make,type k-5, 
 440v,sl.no.50/0254 of muraidih, ampc.
Read moreProviding and fitting safety devices buchholz relay oil and winding temperature indicator for identifying the cause of tripping, and gasket changing of 1250kva transformer 3.3kv/415 volts, make crompton parkinson, serial no. 1546v 1mva tra
Providing and fitting safety devices buchholz relay oil and winding temperature indicator for identifying the cause of tripping, and gasket changing of 1250kva transformer 3.3kv/415 volts, make crompton parkinson, serial no. 1546v 1mva tra
Read moreCork sheet changing, oil filtration etc. and replacement of av alarm along with oti wii of 1000kva 6.6kv550v transformer sl.no.c6520/82 sbc(ii)repairing 02 nos transformer(a)1mva 11kv/6.6kv(b) 1mva,11kv/3.3kv with fitting box in 6.6kv/3.3kv incoming
Cork sheet changing, oil filtration etc. and replacement of av alarm along with oti wii of 1000kva 6.6kv550v transformer sl.no.c6520/82 sbc(ii)repairing 02 nos transformer(a)1mva 11kv/6.6kv(b) 1mva,11kv/3.3kv with fitting box in 6.6kv/3.3kv incoming
Read moreRepairing of (a) 11kv, 600a, gec make ocb switch sl.no.-2817 and (b) 6.6kv,400a gec make ocb switch sl. no.-m-164 for controlling of 11kv/6.6kv transformer at sadbhavna substation under muraidih, amp colliery.
Repairing of (a) 11kv, 600a, gec make ocb switch 
 sl.no.-2817 and (b) 6.6kv,400a gec make ocb 
 switch sl. no.-m-164 for controlling of 11kv/6.6kv 
 transformer at sadbhavna substation under 
 muraidih, amp colliery.
Read moreProviding, fixing and commissioning of buchholz relay temperature meter and its separate annunciation for alarm and trip in 4 no. 630 kva, 3.3kv/440-volt power transformer installed at different place in r.o. kargali ocp.
Providing, fixing and commissioning of buchholz relay temperature meter and its separate annunciation for alarm and trip in 4 no. 630 kva, 3.3kv/440-volt power transformer installed at different place in r.o. kargali ocp.
Read moreof your Industry type