Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Liquid Medical Oxygen Storage Tank,Low Pressure Atmospheric Vaporizer,Pressure Reducing Station,Int
|
| Description |
|
| Organisation | Department of Health and Family Welfare | Ministry of Health and Family Welfare |
| Tender Id | GEM/2025/B/6121912 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | April 23, 2025 21:07 |
| End Date |
Expired
14/05/2025
Expired 519 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Cryogenic liquid nitrogen vertical storage tank capacity 6000 ltr
Cryogenic liquid nitrogen vertical storage tank capacity 6000 ltr
Read moreSupply, design, verification, statutory approval, conversion, testing, installation, commissioning and obtaining statutory approvals from petroleum and explosives safety organization (peso) for conversion of one existing 6000 litre vacuum insulated liquid argon (lar) storage vessel into a liquid oxygen (lox) storage vessel and connecting the converted vessel with the existing oxygen ambient vaporizer through stainless steel pipeline as per scope of work.
Supply, design, verification, statutory approval, conversion, testing, installation, commissioning and obtaining statutory approvals from petroleum and explosives safety organization (peso) for conversion of one existing 6000 litre vacuum insulated liquid argon (lar) storage vessel into a liquid oxygen (lox) storage vessel and connecting the converted vessel with the existing oxygen ambient vaporizer through stainless steel pipeline as per scope of work.
Read moreImplementation of a liquid medical oxygen lmo storage and supply system for 500 plus bedded associated hospital government medical college kathua
Construction of operators rooms and other miscellaneous works as required for liquid medical oxygen system at associated hospital gmc kathua.
Read moreImplementation of a liquid medical oxygen lmo storage and supply system for 500 plus bedded associated hospital government medical college kathua
Design supply installation testing and commissioning of main lmo pipe line from lmo distribution point, along with dedicated medical oxygen pipeline system for critical and other areas of the associated hospital government medical college kathua
Read moreCleaning of all storage tank, ug sump, pressure filter and maint of ro plant including replacement of old unsv gi pipelines of various sizes and other allied works at ins kardip and icgs kamorta
Cleaning of all storage tank, ug sump, pressure filter and maint of ro plant including replacement of old unsv gi pipelines of various sizes and other allied works at ins kardip and icgs kamorta
Read moreCopper alloy taps/stop valves (v2) conforming to is 8931,copper alloy taps/stop valves (v2) conforming to is 8931,copper alloy taps/stop valves (v2) conforming to is 8931,stainless steel sinks for domestic purposes (v3) as per is 13983,stainless steel sinks for domestic purposes (v3) as per is 13983,ewc seat s trap,pvc seat cover for wc e type white colour,gi wire mesh 120cm wide 0 point 50mm dia 1 point 18mm,tubing gi 20mm 6mtr length,water storage tank pvc 500 ltr cap 3 layer,looking mirror 610x450x5mm with frame,pvc syphone kit for low level fc pvc 10 ltr cap internal fitting,water storage tank pvc 500 ltr cap 3 layer,water storage tank pvc 300 ltr cap 2 layer,water storage tank pvc 500 ltr cap 3 layer
Copper alloy taps/stop valves (v2) conforming to is 8931,copper alloy taps/stop valves (v2) conforming to is 8931,copper alloy taps/stop valves (v2) conforming to is 8931,stainless steel sinks for domestic purposes (v3) as per is 13983,stainless steel sinks for domestic purposes (v3) as per is 13983,ewc seat s trap,pvc seat cover for wc e type white colour,gi wire mesh 120cm wide 0 point 50mm dia 1 point 18mm,tubing gi 20mm 6mtr length,water storage tank pvc 500 ltr cap 3 layer,looking mirror 610x450x5mm with frame,pvc syphone kit for low level fc pvc 10 ltr cap internal fitting,water storage tank pvc 500 ltr cap 3 layer,water storage tank pvc 300 ltr cap 2 layer,water storage tank pvc 500 ltr cap 3 layer
Read moreProctoscope transparent disposable self illuminating adult,leak and puncture resistant 1 point 5 ltr sharp collector with red brackets,leak and puncture resistant 5 point 4 ltr sharp collector,gigli saw wire,disposable presoaked surface disinfectant wet wipes 200 wipes slash bottle,nasal cannula for high flow nasal oxygen therapy medium,nasal cannula for high flow nasal therapy small,laparoscopic port 5 mm x 15 cm,covin cautery lead disposable,clear microlaryngeal tube pvc with high volume low pressure cuff 4 point 0,clear microlaryngeal tube pvc with high volume low pressure cuff 5 point 0,clear microlaryngeal tube pvc with high volume low pressure cuff 6 point 0,toomeys syringe 50 ml,packing paper tyvek 200 mm x 80 m,packing paper tyvek 100 mm x 80 m,laparoscopic smoke filter pall
Proctoscope transparent disposable self illuminating adult,leak and puncture resistant 1 point 5 ltr sharp collector with red brackets,leak and puncture resistant 5 point 4 ltr sharp collector,gigli saw wire,disposable presoaked surface disinfectant wet wipes 200 wipes slash bottle,nasal cannula for high flow nasal oxygen therapy medium,nasal cannula for high flow nasal therapy small,laparoscopic port 5 mm x 15 cm,covin cautery lead disposable,clear microlaryngeal tube pvc with high volume low pressure cuff 4 point 0,clear microlaryngeal tube pvc with high volume low pressure cuff 5 point 0,clear microlaryngeal tube pvc with high volume low pressure cuff 6 point 0,toomeys syringe 50 ml,packing paper tyvek 200 mm x 80 m,packing paper tyvek 100 mm x 80 m,laparoscopic smoke filter pall
Read moreBanana fiber extraction machine,banana pseudo stem cutting machine,hydraulic press juicer for sap liquid,waste fiber recovery machine,10 kl digester with agitator system,storage plastic tank,material transfer trolley,liquid filter,collection tray,sap collection tank rectangular,induction sealer,primary filtration unit after collection tank,banana fiber combing machine,conveyor belt,suture collection tray,banana waste leaves sap extractor,banana fiber drying stand,working tables,fiber shredder machine,banana fiber opening machine,automatic fiber cooker with steam generator,fiber pulper machine,agitator assembly or mixer,balance tank or premixing,paper moulding assembly,hydraulic press machine,paper drying chamber,paper straightening machine,automatic paper cutting machine,office file making machine,preparation tank,hand made paper setup,tools and accessories,plumbing work,electrification and civil work,electric control panel,delivery installation and commissioning
Banana fiber extraction machine,banana pseudo stem cutting machine,hydraulic press juicer for sap liquid,waste fiber recovery machine,10 kl digester with agitator system,storage plastic tank,material transfer trolley,liquid filter,collection tray,sap collection tank rectangular,induction sealer,primary filtration unit after collection tank,banana fiber combing machine,conveyor belt,suture collection tray,banana waste leaves sap extractor,banana fiber drying stand,working tables,fiber shredder machine,banana fiber opening machine,automatic fiber cooker with steam generator,fiber pulper machine,agitator assembly or mixer,balance tank or premixing,paper moulding assembly,hydraulic press machine,paper drying chamber,paper straightening machine,automatic paper cutting machine,office file making machine,preparation tank,hand made paper setup,tools and accessories,plumbing work,electrification and civil work,electric control panel,delivery installation and commissioning
Read moreControl valve characteristics,calibration of thermocouple,dynamic response of the u tube manometer,interacting non interacting system,proportional p and proportional integral pi controllers for flow and level control,time constant of the stirred tank heater,temperature control trainer with computer system,pressure control trainer,p i i p convertor,capacitance method,nephelometer or turbidimeter,hot air oven,muffle furnace,jar test apparatus,high volume air sampler pm10,fine particulate sampler pm2.5,biochemical oxygen demand analyzer,cod reflux apparatus with cod digester,bomb calorimeter,biogas digester or anaerobic digester,melting point apparatus,ball mill,air compressor,oil free vacuum pump,ultra violet flourescene inspection cabinet
Control valve characteristics,calibration of thermocouple,dynamic response of the u tube manometer,interacting non interacting system,proportional p and proportional integral pi controllers for flow and level control,time constant of the stirred tank heater,temperature control trainer with computer system,pressure control trainer,p i i p convertor,capacitance method,nephelometer or turbidimeter,hot air oven,muffle furnace,jar test apparatus,high volume air sampler pm10,fine particulate sampler pm2.5,biochemical oxygen demand analyzer,cod reflux apparatus with cod digester,bomb calorimeter,biogas digester or anaerobic digester,melting point apparatus,ball mill,air compressor,oil free vacuum pump,ultra violet flourescene inspection cabinet
Read moreRemoving dry or oil bound distemper, water proofing cement paint,providing and fixing ppr unions 25 mm,providing and placing on terrace at all floor levels polyethylene water storage tank,providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having sun reflectivity index of 105 on top of concrete roof,providing and fixing 19 mm thick both side balancing lamination factory pressed bwp grade marine ply,removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs,providing and applying white cement based putty of average thickness 1 mm,wiring for circuit or submain wiring along with earth wire
Removing dry or oil bound distemper, water proofing cement paint,providing and fixing ppr unions 25 mm,providing and placing on terrace at all floor levels polyethylene water storage tank,providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having sun reflectivity index of 105 on top of concrete roof,providing and fixing 19 mm thick both side balancing lamination factory pressed bwp grade marine ply,removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs,providing and applying white cement based putty of average thickness 1 mm,wiring for circuit or submain wiring along with earth wire
Read moreof your Industry type