Tender Details
Particulars | Details |
---|---|
Title |
Repair/Replacement Of Worn Out 33 Kv Switch Gear,11 Kv Cable, 110 V/52 V/24 V Battery Banks, Maintain To Power Outdoor Transformer Ct,Pt,La, Line Differential Relays, Protective Relays With Accessories Calibration Of Relays/ Breakers At 33 Kv Shankar Vih
|
Description |
Repair/Replacement Of Worn Out 33 Kv Switch Gear,11 Kv Cable, 110 V/52 V/24 V Battery Banks, Maintain To Power Outdoor Transformer Ct,Pt,La, Line Differential Relays, Protective Relays With Accessories Calibration Of Relays/ Breakers At 33 Kv Shankar Vih
|
Organisation | E-IN-C BRANCH - MILITARY ENGINEER SERVICES | Central Govt. Ministry/Department |
Tender Id | 2024_MES_671270_2 |
Reference Number |
CWE(U)/D-13/2024-25 |
Tender Fee | 1000 |
EMD | 1.89 Lakh |
Tender Value | |
Place | HQ CWE (U) DELHI CANTT-10 |
Link | https://defproc.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=766929 |
Start Date | November 29, 2024 23:30 |
End Date |
04/12/2024 ( Expired 138 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Installation of 05 nos. of 1250 a, 33kv, sf6 circuit breakers along with accessories and revival of 33 kv bay of 33000/110v pt side in 15 mva, 33kv/6.6kv new sub-station of kdh ocp, nk area
Installation of 05 nos. of 1250 a, 33kv, sf6 circuit breakers along with accessories and revival of 33 kv bay of 33000/110v pt side in 15 mva, 33kv/6.6kv new sub-station of kdh ocp, nk area
Read moreFor installation of two nos percentage differential relay in 33kv panel of transformer 1 and 2 and dismantling, installation of 33 kv ct at 33 kv side of transformer no 1 and 2 at (33kv/11kv, 10mva) south loyabad sub-station under kusunda area
For installation of two nos percentage differential relay in 33kv panel of transformer 1 and 2 and dismantling, installation of 33 kv ct at 33 kv side of transformer no 1 and 2 at (33kv/11kv, 10mva) south loyabad sub-station under kusunda area
Read more11kv 24v dc ptr lv vcbs with control & relay panels and cts of ratio 400-200-100/1-1a(with out differential protection): 11 kv, 3 pole, 1250 a,50 hz, 25 ka , porcelain clad pad type outdoor vacuum circuit breakers , with outdoor control and relay panels & current transformers , (detailed technical specification attached) . vcb shall be equipped with 24vdc operated outdoor type control and relay panels with 3 o/l & 1e/l idmt numerical relays and 3nos outdoor vcb mounted current transfor
For complete deion and other details, please refer to tender
Read moreRepair/replacement of worn out 33kv switch gear,11kv cable, 110v/52v/24v battery banks, maintain to power outdoor transformer ct,pt,la, line differential relays, protective relays with accessories calibration of relays/ breakers at 33 kv shankar vih
Repair/replacement of worn out 33kv switch gear,11kv cable, 110v/52v/24v battery banks, maintain to power outdoor transformer ct,pt,la, line differential relays, protective relays with accessories calibration of relays/ breakers at 33 kv shankar vih
Read moreRepair/ maint of electric switch gear 33/11kv sub station equipment control panel 33 kv ct/pt and other connected works at mrs at mrs at afs kanpur
Repair/ maint of electric switch gear 33/11kv sub station equipment control panel 33 kv ct/pt and other connected works at mrs at mrs at afs kanpur
Read morePreventive maintenance, calibration and repair of 33 kv, 11 kv feeders and switch gears, vcb relays, apfc panels, ht ug cables/oh lines, transformers and its allied works including battery banks at deal and irde area under ge (i) rnd dehradun
Preventive maintenance, calibration and repair of 33 kv, 11 kv feeders and switch gears, vcb relays, apfc panels, ht ug cables/oh lines, transformers and its allied works including battery banks at deal and irde area under ge (i) rnd dehradun
Read moreOnsite testing and calibration of protective relays and high voltage injection of circuit breakers ad dga analysis of transformer oil installed at 33 kv main substation of akkocp, bnk area
Onsite testing and calibration of protective relays and high voltage injection of circuit breakers ad dga analysis of transformer oil installed at 33 kv main substation of akkocp, bnk area
Read moreRepair replacement of worn out 33kv switchgear pads and replacement of 110 v 52v 24v battery banks maintanence of power outdoor indoor distribution transformer ct pt la line differential relays protective relays with accessories calibration of relays
Repair replacement of worn out 33kv switchgear pads and replacement of 110 v 52v 24v battery banks maintanence of power outdoor indoor distribution transformer ct pt la line differential relays protective relays with accessories calibration of relays
Read moreRepair/replacement of worn out 33kv switchgear pads and replacement of 110 v / 52v/ 24v battery banks, maintanence of power outdoor /indoor distribution transformer ct,pt,la, line differential relays, protective relays with accessories calibration of
Repair/replacement of worn out 33kv switchgear pads and replacement of 110 v / 52v/ 24v battery banks, maintanence of power outdoor /indoor distribution transformer ct,pt,la, line differential relays, protective relays with accessories calibration of
Read moreSupply, installation, testing and commissioning of 132kv ct set for 400mva transformer and 11kv nct set for 160mva and 400mva transformers after replacement of said old/ worn out equipments at 710 mva, 220/132/33 kv grid station, gladni
Supply, installation, testing and commissioning of 132kv ct set for 400mva transformer and 11kv nct set for 160mva and 400mva transformers after replacement of said old/ worn out equipments at 710 mva, 220/132/33 kv grid station, gladni
Read moreof your Industry type