Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Urgent Servicing Of Ht Circuit Breaker Make Schneider Qty 04 Nos. At New Hospicio South Goa District Hospital Margao Goa
|
| Description |
Urgent Servicing Of Ht Circuit Breaker Make Schneider Qty 04 Nos. At New Hospicio South Goa District Hospital Margao Goa
|
| Organisation | Government of Goa |
| Tender Id | 2023_PWD_9776_1 |
|
Reference Number |
3/23-24/PWD/WDXXII /MnE/ASW/TN-06/02 dtd 4/7/23 |
| Tender Fee | 1000 |
| EMD | 1840 |
| Tender Value | - |
| Place | WD XXII PWD FATORDA |
| Link |
View Original Tender Notice
https://eprocure.goa.gov.in |
| Start Date | July 05, 2023 16:00 |
| End Date |
Expired
02/08/2023
Expired 1169 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Servicing and overhauling of compressor unit of 400kv circuit breaker at 400kv sub station sarnath, varanasi.
Servicing and overhauling of compressor unit of 400kv circuit breaker at 400kv sub station sarnath, varanasi.
Read moreController pn tm200ce24r make schneider,analog input module,tesys gv2 circuit breaker,tesys d contactor,tesysd contactor lc1d32bd,hmi touch screen panel
Controller pn tm200ce24r make schneider,analog input module,tesys gv2 circuit breaker,tesys d contactor,tesysd contactor lc1d32bd,hmi touch screen panel
Read moreRepair and maint of transformer vaccum circuit breaker servo voltage stabilizer and other ht panel ct/pt and ht cable ht joint and other misc connected workt at bhdc under ge (east) delhi cantt-10
Repair and maint of transformer vaccum circuit breaker servo voltage stabilizer and other ht panel ct/pt and ht cable ht joint and other misc connected workt at bhdc under ge (east) delhi cantt-10
Read moreRepair/replacement/servicing of ht supply system including ht cables, oil circuit breakers, ht panels and connected works at 512 abws and cafvd tech area in age e/m-ii under ge (c) khadki
Repair/replacement/servicing of ht supply system including ht cables, oil circuit breakers, ht panels and connected works at 512 abws and cafvd tech area in age e/m-ii under ge (c) khadki
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreUrgent servicing of ht circuit breaker make schneider, qty 04 nos. at new hospicio south goa district hospital, margao-goa.call no. 2
Urgent servicing of ht circuit breaker make schneider, qty 04 nos. at new hospicio south goa district hospital, margao-goa.call no. 2
Read moreUrgent servicing of air circuit breaker make l and t qty 30 nos. at new hospicio south goa district hospital margao-goa
Urgent servicing of air circuit breaker make l and t qty 30 nos. at new hospicio south goa district hospital margao-goa
Read moreUrgent servicing of air circuit breaker make l and t, qty 30 nos. at new hospicio south goa district hospital, margao-goa.call no. 2
Urgent servicing of air circuit breaker make l and t, qty 30 nos. at new hospicio south goa district hospital, margao-goa.call no. 2
Read moreUrgent repairs to the oltc, including servicing and replacement mandatory spares of transformer no, 3 at hospicio south goa district hospital, margao-goa
Urgent repairs to the oltc, including servicing and replacement mandatory spares of transformer no, 3 at hospicio south goa district hospital, margao-goa
Read moreArc for servicing of areva / schneider make ht vacuum circuit breaker at cpcl manali
Arc for servicing of areva / schneider make ht vacuum circuit breaker at cpcl manali
Read moreof your Industry type