Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing Of Two No Ht Er And Two No. Vcb (3.3 Kv, 400 A) Installed At Different Location Of Religara Ocp Under Argada Area.
|
| Description |
Repairing Of Two No Ht Er And Two No. Vcb (3.3 Kv, 400 A) Installed At Different Location Of Religara Ocp Under Argada Area.
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_CCL_323314_1 |
|
Reference Number |
PE(EnM)/Rel/e-NIT/24-25/16 |
| Tender Fee | 0 |
| EMD | 9400 |
| Tender Value | - |
| Place | Religara |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=335136 |
| Start Date | December 13, 2024 20:30 |
| End Date |
Expired
21/12/2024
Expired 662 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repair/replacement/maintenance of distribution transformer, ht ug cables, vcb/ocb/lbs, oh line, two/four pole structure, lightening arrestors and other allied works at afs tambaram
Repair/replacement/maintenance of distribution transformer, ht ug cables, vcb/ocb/lbs, oh line, two/four pole structure, lightening arrestors and other allied works at afs tambaram
Read moreProviding lightning arrestor, earthing ,cradle guard and erection of poles, etc and dismantling of poles, conductor,etc near mahalaxmi camp sub station and its 3.3kv ht line under ashok west ocp, piparwar area.
Providing lightning arrestor, earthing ,cradle guard and erection of poles, etc and dismantling of poles, conductor,etc near mahalaxmi camp sub station and its 3.3kv ht line under ashok west ocp, piparwar area.
Read moreComprehensive annual maintenance contract(camc) for dismantling and laying of different dia ms/gi pipes, valves etc. as and when required basis for smooth mine dewatering and fire quenching for a period of 02(two) year at sirka ocp under argada
Comprehensive annual maintenance contract(camc) for dismantling and laying of different dia ms/gi pipes, valves etc. as and when required basis for smooth mine dewatering and fire quenching for a period of 02(two) year at sirka ocp under argada
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreRepairing of two no ht er and two no vcb under religara project
Repairing of two no ht er and
 two no. vcb (3.3kv, 400a)
 installed at different location of
 religara ocp under argada area
Read moreRepairing and reconditioning of 3.3kv,60amp,250 kw prabhu make ht er of religara colliery under argada area.
Repairing and reconditioning of 3.3kv,60amp,250 kw prabhu make ht er of religara colliery under argada area.
Read moreVcb 630a, 3.3kv, outdoor type,vcb 400a, 3.3kv, outdoor type,vcb 400a, 3.3kv, indoor type,vcb 1250a,
Read more
Repairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp.
Repairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp.
Read moreRepairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp
Repairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp
Read moreRepairing and reconditioning of 3.3kv, 336 kw, 60amp ht starter of religara colliery under argada area