Repairing Of Two No Ht Er And Two No. Vcb (3.3 Kv, 400 A) Installed At Different Location Of Religara Ocp Under Argada Area.
Description
Repairing Of Two No Ht Er And Two No. Vcb (3.3 Kv, 400 A) Installed At Different Location Of Religara Ocp Under Argada Area.
Organisation Central Coalfields Limited | Public Sector Undertakings
Tender Id 2024_CCL_323314_1
Reference
Number
PE(EnM)/Rel/e-NIT/24-25/16
Tender Fee 0
EMD 9400
Tender Value -
Place Religara
Link
View Original Tender Notice

https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=335136

Start Date December 13, 2024 20:30
End Date
Expired 21/12/2024

Expired 662 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Repair/replacement/maintenance of distribution transformer, ht ug cables, vcb/ocb/lbs, oh line, two/four pole structure, lightening arrestors and other allied works at afs tambaram

Repair/replacement/maintenance of distribution transformer, ht ug cables, vcb/ocb/lbs, oh line, two/four pole structure, lightening arrestors and other allied works at afs tambaram

Read more
Providing lightning arrestor, earthing ,cradle guard and erection of poles, etc and dismantling of poles, conductor,etc near mahalaxmi camp sub station and its 3.3kv ht line under ashok west ocp, piparwar area.

Providing lightning arrestor, earthing ,cradle guard and erection of poles, etc and dismantling of poles, conductor,etc near mahalaxmi camp sub station and its 3.3kv ht line under ashok west ocp, piparwar area.

Read more
Comprehensive annual maintenance contract(camc) for dismantling and laying of different dia ms/gi pipes, valves etc. as and when required basis for smooth mine dewatering and fire quenching for a period of 02(two) year at sirka ocp under argada

Comprehensive annual maintenance contract(camc) for dismantling and laying of different dia ms/gi pipes, valves etc. as and when required basis for smooth mine dewatering and fire quenching for a period of 02(two) year at sirka ocp under argada

Read more
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro

Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro

Read more
Repairing of two no ht er and two no vcb under religara project

Repairing of two no ht er and&#x0d two no. vcb (3.3kv, 400a)&#x0d installed at different location of&#x0d religara ocp under argada area

Read more
Repairing and reconditioning of 3.3kv,60amp,250 kw prabhu make ht er of religara colliery under argada area.

Repairing and reconditioning of 3.3kv,60amp,250 kw prabhu make ht er of religara colliery under argada area.

Read more
Repairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp.

Repairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp.

Read more
Repairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp

Repairing and reconditioning of 02 no. 3.3kv ht er, 01 no. 550 v er and 02 no. 3.3kv vcb switch installed at sirka ocp

Read more
Repairing and reconditioning of 3.3kv, 336 kw, 60amp ht starter of religara colliery under argada area

Repairing and reconditioning of 3.3kv, 336 kw, 60amp ht starter of religara colliery under argada area