Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
About Tender
🛡️ Procurement Opportunity: Stent Purchase For Ministry Of Defence 🩺 The Department Of Military Affairs, Under The Ministry Of Defence, Is Seeking Bids For The Procurement Of Everliomus Eluting Cobalt Chromium Stents With A Thinness Of 0.00332 Inches And A Fluorinated Copolymer Multilink Design. 🗓️ Deadline: June 1, 2024, 10:00 Am Bids Should Be Comprehensive, Detailing The Technical Specifications, Pricing, And Delivery Schedules, In Compliance With The Stringent Quality Standards Required By The Ministry. Keywords: Stent, Everliomus Eluting, Cobalt Chromium, Thinness 0.00332, Fluorinated Copolymer, Multilink, Ministry Of Defence, Procurement Tender| Particulars | Details |
|---|---|
| Title |
Everliomus Eluting Cobalt Chromium Des Thinstruct Thickness 0.00332 Fluorinated Copolymer Multilink
|
| Description |
|
| Organisation | Department of Military Affairs | Ministry of Defence |
| Tender Id | GEM/2024/B/4922814 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | May 11, 2024 15:20 |
| End Date |
Expired
01/06/2024
Expired 869 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | MSE/MII Status | Status |
|---|---|---|---|---|---|
| 1 | CONTINENTAL DRUG STORES | Make : ISAR SUMMIT/TRANSLUMINA Model : ISAR SUMMIT Title : COBALT CHROMIUM EVEROLIMUS ELUTING 4TH GENERATION CORONARY STENT ASSORTED SIZES | 31-05-2024 17:19:22 | N/A | Evaluated |
Sirolimus eluting coronary stent system with biodegradable polymer on cobalt chromium platform with active coating per set
Sirolimus eluting coronary stent system with biodegradable polymer on cobalt chromium platform with active coating per set
Read moreHq_med_sur_ph:.(153049) drug eluting coronary stent system - platinum chromium hdvd - pvf everolimus drug eluting stent 2.25 mm to 4 mm all size
Hq_med_sur_ph:.(153049) drug eluting coronary stent system - platinum chromium hdvd - pvf everolimus drug eluting stent 2.25 mm to 4 mm all size
Read moreHq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved
Hq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved
Read moreEverolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Everolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Read moreModular bipolar hip prosthesis set consisting of femoral stem-01, titanium alloy make, proximal stem h a coated , morphometric wedge design which fits for a wide range of femoral canal and to have two neck angles, 02- femoral head cobalt chromium-1no. 03-bipolar component cobalt with highly cross lined poly lining
Modular bipolar hip prosthesis set consisting of femoral stem-01, titanium alloy make, proximal stem h a coated , morphometric wedge design which fits for a wide range of femoral canal and to have two neck angles, 02- femoral head cobalt chromium-1no. 03-bipolar component cobalt with highly cross lined poly lining
Read moreUltraporous acetabular shell with compatible crosslinked polyethylene liner with two screw (size 44/,revision acetabular cup with ischial flange/peripheral rim screws (to include 08 screws) /(size 56/58,posterior stabilised knee consisting of: cobalt chromium femoral component matching highly crosslin
Ultraporous acetabular shell with compatible crosslinked polyethylene liner with two screw (size 44/,revision acetabular cup with ischial flange/peripheral rim screws (to include 08 screws) /(size 56/58,posterior stabilised knee consisting of: cobalt chromium femoral component matching highly crosslin
Read moreVascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Vascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Read moreCoronary stent- sirolimus eluting eluting des, cobalt chromium platform having biodegradable polyme
Read more
of your Industry type