Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Anaerobic Adhesives Used For Application Such As Thread Locking Of Bolts And Nuts, Studs, Screws Of Various Shape And Sizes As Per The Following Detailed Technical Specification:
(1) Curing Time:5 12 Min, Full Strength: 3 Hrs. (2) Viscosity: 1150 1350 Cps 30 Degree Celsius. (3) Gap Filled: 0.25mm. (4) Service Temperature: 60 To 200 Degree Celsius. (5) Colour: Green. (6) Breakaway Torque: 3.3 3.7 Kgm. (7) Prevaling Torque: 3.4 4.0 Kgm. (8) Specific Gravity At 30 Degree Celsius : 1.0 1.1
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106508678 |
|
Reference Number |
02241579A |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Bhubaneswar |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/112024/106508678/viewNitPdf_4754816.pdf |
| Start Date | October 25, 2024 16:22 |
| End Date |
Expired
18/11/2024
Expired 660 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Water hose pipe(rubber) of 10 mtrs length for coach washing hose id 3/8 inches, maximum working pressure 450 bar working temperature range -40 degree celsius to 100 degree celsius,
For complete deion and other details, please refer to tender
Read moreWater hose pipe(rubber) of 10 mtrs length for coach washing hose id 3/8 inches, maximum working pressure 450 bar working temperature range -40 degree celsius to 100 degree celsius,
For complete deion and other details, please refer to tender
Read morePower contactors, 3 pole, 1000v ac operation voltage, 50 hz, suitable for 100 kva, 750 v ac, onload switching at temperature of 70 degree celsius & coil voltage of 110 v 25 percent -30 percent dc at temperature of 70 degree celsius
For complete deion and other details, please refer to tender
Read moreSupply installation commissioning of test panel for temperature sensor checking of 3 phase locomotive (tm) with calibrator ambient temperature to 300 degree celsius
For complete deion and other details, please refer to tender
Read moreAnaerobic adhesive sealant in a plastic container of 50 ml tube bottle type: anr-138 of m/s. pidilite/mumbai or equivalent to use on mp & ip fixing bolts of traction motor and to the following parameters. 1.viscosity 2000 - 2500 cps. 2.static shear strength 250 - 300 kgs/cm 3.breakaway torque 250 - 450 kgs-cm.4.prevailing torque 150 - 200 kgs-cm 5.gap filling 0.25mm. 6.setting time 10 -20 minutes. 7.temp. resistance (-) 60 degree c to () 180 degree c
For complete deion and other details, please refer to tender
Read moreThread locker anaerobic sealant for securing & sealing of bolts & studs as per technical specifications specified below. (1). viscosity:800 -1000 cps. (2). static shear strength:150 - 250 kg/sq.cm. (3).breakaway torque:150 - 300 kg.cm. (4).prevailing torque:100 - 250 kg.cm. (5).gap filling : 0.25mm. (6).setting time : 05 - 20 minutes. (7).temperature resistance : - 60 to 180 degree c. makes: fevicol anr 124/ my-t-lok 352/ anabond 115/ loctite 271. note: 1) each bottle/ tube of 50ml capacit
For complete deion and other details, please refer to tender
Read moreSet of items consisting of [1]. thermometer 100 degree celsius without calibration certificate, qty-03 nos. (shall confirm to is 2480, (part-1)/1983, reaffirmed 2022, schedule mark, tl/p1 4 or 5, or astm 7c/ip 5c and astm7f) [2]. thermometer 100 degree celsius with calibration certificate, qty-01 no. (shall confirm to is 2480, (part-1)/1983, reaffirmed 2022, schedule mark, tl/p1 4 or 5, or astm 7c/ip 5c and astm7f) [3]. thermometer 400 degree celsius with calibration certificate, qty-01 no
For complete deion and other details, please refer to tender
Read moreSet of items consisting of [1]. thermometer 100 degree celsius without calibration certificate, qty-03 nos. (shall confirm to is 2480, (part-1)/1983, reaffirmed 2022, schedule mark, tl/p1 4 or 5, or astm 7c/ip 5c and astm7f) [2]. thermometer 100 degree celsius with calibration certificate, qty-01 no. (shall confirm to is 2480, (part-1)/1983, reaffirmed 2022, schedule mark, tl/p1 4 or 5, or astm 7c/ip 5c and astm7f) [3]. thermometer 400 degree celsius with calibration certificate, qty-01 no
For complete deion and other details, please refer to tender
Read moreRadiator motor for lhb power car: 3 phase squirrel cage induction motor 30 hp,22 kw, voltage 415v /-10 percent , freq:50hz, rpm:1460, ip-55, amb:50 degree celsius, pf:>/=0.8, efficiency:>/=89.9 percent , insulation class f
For complete deion and other details, please refer to tender
Read moreRadiator motor for lhb power car: 3 phase squirrel cage induction motor 30 hp,22 kw, voltage 415v /-10 percent , freq:50hz, rpm:1460, ip-55, amb:50 degree celsius, pf:>/=0.8, efficiency:>/=89.9 percent , insulation class f
For complete deion and other details, please refer to tender
Read moreof your Industry type