Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Contact Wire Swivel Clip Complete Parts As Per Drg. No. Re/33/P/1220 Rev E & Id No. 1221 Or Latest.
|
| Description |
Contact Wire Swivel Clip Complete Parts As Per Drg. No. Re/33/P/1220 Rev E & Id No. 1221 Or Latest.
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 05, 2026 16:30 |
| End Date |
Open
02/11/2026
18 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Contact wire splice (toothed type), complete assembly as per rdso drg. no. eti/ohe/p/1080-1 (rev- b) or latest.
Contact wire splice (toothed type), complete assembly as per rdso drg. no. eti/ohe/p/1080-1 (rev- b) or latest.
Read moreLong life loco side buffer assemly (capacity 30 kj minimum) clw drg./ specn. no. rdso drg no. sk.dl- 4748 alt 2 or latest and rdso spec no mp-0.41.00.03 (rev.03) august 2024 or latest.(as per uvam id: 3100251).
Long life loco side buffer assemly (capacity 30 kj minimum) clw drg./ specn. no. rdso drg no. sk.dl- 4748 alt 2 or latest and rdso spec no mp-0.41.00.03 (rev.03) august 2024 or latest.(as per uvam id: 3100251).
Read more36 mm aluminium bus terminal of aluminium alloy for 25 kv isolator (rigid type) as per rdso drawing no. eti/psi/p/6480 (rev-c) and id nos. 6481 & 6482 or latest.
36 mm aluminium bus terminal of aluminium alloy for 25 kv isolator (rigid type) as per rdso drawing no. eti/psi/p/6480 (rev-c) and id nos. 6481 & 6482 or latest.
Read moreContact wire ending clamp body (part no.1118-3) and wedge (part no.1119-3) with fasteners suitable for 107 sq. mm contact wire as per rdso drg. no. eti/ohe/p/1110-2 rev-e and rdso s spec. no. ti/spc/ohe/fittings/0130(10/13) rev. 1 or latest & no. eti/ohe/13(4/84) a & c slip no.1 to 4
Contact wire ending clamp body (part no.1118-3) and wedge (part no.1119-3) with fasteners suitable for 107 sq. mm contact wire as per rdso drg. no. eti/ohe/p/1110-2 rev-e and rdso s spec. no. ti/spc/ohe/fittings/0130(10/13) rev. 1 or latest & no. eti/ohe/13(4/84) a & c slip no.1 to 4
Read moreMotor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.
Motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.
Read moreTriplate air brake panel of irab-9/irab- [triplate air brake panel of irab-9/irab-10 brake system complete for conventional locomotives as per spec.no.elrs/spec/pbs/0034(rev.1) april 2005 with latest amendment if any (as per uvam id: 2101176).]
Triplate air brake panel of irab-9/irab- [triplate air brake panel of irab-9/irab-10 brake system complete for conventional locomotives as per spec.no.elrs/spec/pbs/0034(rev.1) april 2005 with latest amendment if any (as per uvam id: 2101176).]
Read morePvc flooring roll 2 x 1850 x 14000 mm, colour as per sample no. nacflg-02, as per drawing/specification: rdso/200 6/cg-12, rev.2 of sept-2023 or latest, with pvc welding electrode dia 4mm=12 mtrs. per roll. item to be procured from rcf approved sources only. rcf item id: 2400073
Pvc flooring roll 2 x 1850 x 14000 mm, colour as per sample no. nacflg-02, as per drawing/specification: rdso/200 6/cg-12, rev.2 of sept-2023 or latest, with pvc welding electrode dia 4mm=12 mtrs. per roll. item to be procured from rcf approved sources only. rcf item id: 2400073
Read morePower connectors 24 pins with crimped terminal in rmpu make: harting make han e-type/widmuiller/phoenix/lapp or any other equivalent make having interchangeability of connectors and its parts with prior approval of rdso (part number as per annexure-vi) of rmpu of lhb ac coaches, conforming to rdso specification no. rdso/pe/spec/ac/0061-2005 (rev. 2) or latest
Power connectors 24 pins with crimped terminal in rmpu make: harting make han e-type/widmuiller/phoenix/lapp or any other equivalent make having interchangeability of connectors and its parts with prior approval of rdso (part number as per annexure-vi) of rmpu of lhb ac coaches, conforming to rdso specification no. rdso/pe/spec/ac/0061-2005 (rev. 2) or latest
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Read moreAir circuit breaker (acb) suitable for lhb power car of system voltage-750 v, capacity-800 amp, breaking capacity-50ka, frequency-50 hz, 3 pole mf (with inbuilt uv protection, thermal, magnetic release), 6 no + 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type: cn-cs 800c conforming to rcf specification no: edts 103, rev-d, am-07 or latest, make- lauritz knudsen formerly l&t/abb/ge only.
Air circuit breaker (acb) suitable for lhb power car of system voltage-750 v, capacity-800 amp, breaking capacity-50ka, frequency-50 hz, 3 pole mf (with inbuilt uv protection, thermal, magnetic release), 6 no + 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type: cn-cs 800c conforming to rcf specification no: edts 103, rev-d, am-07 or latest, make- lauritz knudsen formerly l&t/abb/ge only.
Read moreof your Industry type