Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Additional Estimate For New 11 Kv Feeder To Bifurcate The Load Of 11 Kv Jamunipur Feeder
|
| Description |
Additional Estimate For New 11 Kv Feeder To Bifurcate The Load Of 11 Kv Jamunipur Feeder Emanated From Carpet City, Bhadohi. (Semi Turnkey)
|
| Organisation | Purvanchal Vidyut Vitran Nigam Limited Varanasi | State Govt. and UT |
| Tender Id | 2025_PVVNV_1068453_1 |
|
Reference Number |
11/EWC(M)/2025-26 |
| Tender Fee | 1180 |
| EMD | 3400 |
| Tender Value | - |
| Place | Superintending Engineer Electricity Work Circle |
| Link |
View Original Tender Notice
https://etender.up.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=1949081 |
| Start Date | August 26, 2025 14:30 |
| End Date |
Expired
10/09/2025
Expired 395 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Erection of 1 no. 33 kv feeder bay at 132 kv ss ibrahimpatnam for extension of supply to m/s. tgsrtc ibrahimpatnam
Erection of 1 no. 33 kv feeder bay at 132 kv ss ibrahimpatnam for extension of supply to m/s. tgsrtc ibrahimpatnam
Read moreEstimate for interlinking of 33kv uttaraspally feeder and 33kv kv chowderguda feeder for providing of alternate power suplly to thummalapally ss, veerannapet and chowderguda ss during break downs and other maintainance works in kondurg section in shadanagar sub division in shadnagar division in rajendranagar circle under summer action plan.
Estimate for interlinking of 33kv uttaraspally feeder and 33kv kv chowderguda feeder for providing of alternate power suplly to thummalapally ss, veerannapet and chowderguda ss during break downs and other maintainance works in kondurg section in shadanagar sub division in shadnagar division in rajendranagar circle under summer action plan.
Read moreBifurcation of 11 kv medibavi feeder (185111340102) emanating from 33/11 kv seethaphalmandi ss by erection of new 11kv feeder from 33/11kv ou ss which involves laying of 1.94 km 11kv3x300sq.mm xlpe ug cable (single run) up to the master minds school warasiguda through under pass railway bridge near ou cycling stadium via ou ss h adikmet main road, bouda nagar rd, warasiguda rd no 1 along with erection of 1no. 11 kv feeder vcb at 33/11kv ou ss in seethaphalmandi section of padmarao nagar sub-divi
Bifurcation of 11 kv medibavi feeder (185111340102) emanating from 33/11 kv seethaphalmandi ss by erection of new 11kv feeder from 33/11kv ou ss which involves laying of 1.94 km 11kv3x300sq.mm xlpe ug cable (single run) up to the master minds school warasiguda through under pass railway bridge near ou cycling stadium via ou ss h adikmet main road, bouda nagar rd, warasiguda rd no 1 along with erection of 1no. 11 kv feeder vcb at 33/11kv ou ss in seethaphalmandi section of padmarao nagar sub-division in paradise division of secunderabad circle and the work executed by construction division of secunderabad circle under t and d improvements to original works reserved under sc category
Read moreRenovation and improvements to existing control house for providing additional space for accomodating telecom equipment at 220/132 kv ss durshed in omc circle,karimnagar of karimnagar zone.
Renovation and improvements to existing control house for providing additional space for accomodating telecom equipment at 220/132 kv ss durshed in omc circle,karimnagar of karimnagar zone.
Read moreTurnkey contract for installation of 14 nos. of additional 5 mva departmental power transformer along with associated 33 kv & 11 kv protection system and 11 kv bay at different power sub station in electric supply circle, begusarai, darbhanga, saharsa, kishanganj and purnea under o&m capital head/ internal resource fund (irf), o&m department, nbpdcl.
Turnkey contract for installation of 14 nos. of additional 5 mva departmental power transformer along with associated 33 kv & 11 kv protection system and 11 kv bay at different power sub station in electric supply circle, begusarai, darbhanga, saharsa, kishanganj and purnea under o&m capital head/ internal resource fund (irf), o&m department, nbpdcl.
Read moreProviding of 17 nos. new individual dedicated earth pits for each phase of lightning arrestors (las),duly connecting to existing switchyard earth mat of various feeder bays at 220/132/33 kv ss, mahabubnagar (bhoothpur).
Providing of 17 nos. new individual dedicated earth pits for each phase of lightning arrestors (las),duly connecting to existing switchyard earth mat of various feeder bays at 220/132/33 kv ss, mahabubnagar (bhoothpur).
Read moreSupply of material / equipment including transportation, insurance, delivery, erection, testing, commissioning and civil construction works of (i) erection of 132/11kv sub-station at vellatur (v), chintalapalem (m) (ii) erection of 132kv dc line to the proposed 132/11kv vellatur ss from existing 220/132 kv sithapuram ss (20 km), (iii) erection of 2 nos. 132kv feeder bays at existing 220/132kv sithapuram ss in suryapet district under mukthyala branch canal lift irrigation scheme on turnkey basis
Supply of material / equipment including transportation, insurance, delivery, erection, testing, commissioning and civil construction works of (i) erection of 132/11kv sub-station at vellatur (v), chintalapalem (m) (ii) erection of 132kv dc line to the proposed 132/11kv vellatur ss from existing 220/132 kv sithapuram ss (20 km), (iii) erection of 2 nos. 132kv feeder bays at existing 220/132kv sithapuram ss in suryapet district under mukthyala branch canal lift irrigation scheme on turnkey basis.
Read moreAt present on 11 kv naagdevta feeder load is peak load 180 amp. so it is bifurcate essential. hence estimate framed accordingly
At present on 11 kv naagdevta feeder load is peak load 180 amp. so it is bifurcate essential. hence estimate framed accordingly
Read moreConstruction of 11 kv line for alpha tower feeder which will bifurcate/ load sharing of shanti vihar and saraswati vihar feeder edsd araghar.
Construction of 11 kv line for alpha tower feeder which will bifurcate/ load sharing of shanti vihar and saraswati vihar feeder edsd araghar.
Read moreConstruction of u/g 11 kv feeder from 33/11kv s/s alaipur to bifurcate the load of 11kv konia feeder emitting from 33/11 kv s/s kashi
The work for construction of u/g 11 kv feeder from 33/11kv s/s alaipur to bifurcate the load of 11kv konia feeder emitting from 33/11 kv s/s kashi in the area of uedd-viii varanasi, under ee, uecd-ii, varanasi in business plan 2025-26 on semi turn ke