Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Emergency Battery Charger (230 V Ac/110 V Dc, Capacity 2.5 Kw , Current 20 Amps ) Suitable For Lhb Type Power Car, Ac Coaches
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106267618 |
|
Reference Number |
LY235600B |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Secunderabad |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/032024/106267618/viewNitPdf_4481437.pdf |
| Start Date | February 13, 2024 21:08 |
| End Date |
Expired
05/03/2024
Expired 957 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
4.5 kw regulated cum emergency battery charger
4.5 kw regulated cum emergency battery charger
Read more2.5 kw underslung type constant voltage regulated battery charger
2.5 kw underslung type constant voltage regulated battery charger
Read moreSupply of 4.5 kw underslung constant voltage regulated cum emergency battery charger
Supply of 4.5 kw underslung constant voltage regulated cum emergency battery charger
Read moreIndustrial heavy duty portable welding machine arc 250-amps with standard accessories electrode holder with earth & working clamp with 1.5 mtr cable and euro connectors, specification : voltage-230v, dimension375x155x232mm approx., current-250 a, body-steel and fiber, weight-approx 7 kg
Industrial heavy duty portable welding machine arc 250-amps with standard accessories electrode holder with earth & working clamp with 1.5 mtr cable and euro connectors, specification : voltage-230v, dimension375x155x232mm approx., current-250 a, body-steel and fiber, weight-approx 7 kg
Read more24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
Read moreDin type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Read moreSupply of one coach set of axle mounted disc brake system for lhb type power car coaches as per rdso specification no. rdso-2011/cg-04, rev-03, latest (rev./amd). scope of supply shall be as per clause 9.2 of rdso specification no. rdso-2011/cg-04, rev-03, latest (rev./amd) without brake disc, emergency brake cable box npz 1-s or passenger emergency pilot valve, passenger emergency alarm valve & ep assist equipment. make- knorr-bremse (pac) (hsn code. 86079100)
Supply of one coach set of axle mounted disc brake system for lhb type power car coaches as per rdso specification no. rdso-2011/cg-04, rev-03, latest (rev./amd). scope of supply shall be as per clause 9.2 of rdso specification no. rdso-2011/cg-04, rev-03, latest (rev./amd) without brake disc, emergency brake cable box npz 1-s or passenger emergency pilot valve, passenger emergency alarm valve & ep assist equipment. make- knorr-bremse (pac) (hsn code. 86079100)
Read morePower contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.
Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.
Read more3 kvar metalized polypropylene gas filled, wavy cut three phase self-healing type capacitors, rated at 480v, 50hz, rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1): 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confirm
3 kvar metalized polypropylene gas filled, wavy cut three phase self-healing type capacitors, rated at 480v, 50hz, rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1): 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confirm
Read more3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1) : 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confir
3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1) : 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confir
Read moreof your Industry type