Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Supply & Safe Delivery Of Eye Sling Hook Of Safe Working Load Capacity 12.5 Ton As Per Attached Spec
|
| Description |
|
| Organisation | Department of Atomic Energy | PMO |
| Tender Id | GEM/2025/B/6473574 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | July 25, 2025 20:52 |
| End Date |
Expired
04/08/2025
Expired 439 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Set of four leg wire rope sling with master and intermediate link at one end and eye hook at another end as per attached annexure -a .
Set of four leg wire rope sling with master and intermediate link at one end and eye hook at another end as per attached annexure -a .
Read moreSupply safe delivery, testing and warranty of all-in-one pcs as per attached specification
Supply safe delivery, testing and warranty of all-in-one pcs as per attached specification
Read moreWorking table for coil taping of 3phase tm stator coil as per attached spec
Working table for coil taping of 3phase tm stator coil as per attached spec
Read moreFour-legged chain sling with master link [four-legged chain sling with master link assembly at top and eye hook at bottom, confrming to specifcation: is: 2760 (1980) & is: 3822 (2002), detail specifcation: annexure-a (attached) make: amir or reputed similar oem (load test certifcate from govt. approved lab and material test certifcate from nabl approved lab to be provided)]
Four-legged chain sling with master link [four-legged chain sling with master link assembly at top and eye hook at bottom, confrming to specifcation: is: 2760 (1980) & is: 3822 (2002), detail specifcation: annexure-a (attached) make: amir or reputed similar oem (load test certifcate from govt. approved lab and material test certifcate from nabl approved lab to be provided)]
Read moreTrestle for lhb coaches to lgds drg.no.c&w.lgd.sk.no.1071, alt-nil. accepted make : pli. the minimum safe working load capacity of each trestles must be 20 tons and the proof load capacity should be 30 tones.
Trestle for lhb coaches to lgds drg.no.c&w.lgd.sk.no.1071, alt-nil. accepted make : pli. the minimum safe working load capacity of each trestles must be 20 tons and the proof load capacity should be 30 tones.
Read moreHeavy duty high tenacity 100 percent polyester flat duplex webbing sling, having rein forced eye loop at both end. capacity- 3 ton, length- 3 mtr. and width- 75 mm. (to be supplied with load test certificate from government approved test house)
Heavy duty high tenacity 100 percent polyester flat duplex webbing sling, having rein forced eye loop at both end. capacity- 3 ton, length- 3 mtr. and width- 75 mm. (to be supplied with load test certificate from government approved test house)
Read moreMain compressor assembly for electric locos, 1000 liters per minute capacity with driving motor 14 hp, 10.4 kw rating, speed 1000 rpm, working pressure 10.5 kg/ sq.cm, free air delivery 1000 lpm with h class insulation as per clw spec, no clw/es/c-34 alt.o (as per uvam id:2100711).
Main compressor assembly for electric locos, 1000 liters per minute capacity with driving motor 14 hp, 10.4 kw rating, speed 1000 rpm, working pressure 10.5 kg/ sq.cm, free air delivery 1000 lpm with h class insulation as per clw spec, no clw/es/c-34 alt.o (as per uvam id:2100711).
Read moreWorking and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Working and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Read more1 in 12 tws turnout for 22.9t axle load for 10125 mm curved switch with 60e1a1 thick web tongue rails for 1 in 12 turnout b.g. (1673 mm) for 60e1 rail with r260 grade on psc sleepers (drawings and item details as mentioned in set document are applicable) drg: (rdso) rdso/t-8780 alt.4 spec: (rdso) irs/t-10-2025 set doc: set_rt_8780_ alt_4.precruving requirements as per the perm yard (sse/p.way/con-i/dmv) is must. attached calculation sheet with tender to be refered to for precurving requirement
1 in 12 tws turnout for 22.9t axle load for 10125 mm curved switch with 60e1a1 thick web tongue rails for 1 in 12 turnout b.g. (1673 mm) for 60e1 rail with r260 grade on psc sleepers (drawings and item details as mentioned in set document are applicable) drg: (rdso) rdso/t-8780 alt.4 spec: (rdso) irs/t-10-2025 set doc: set_rt_8780_ alt_4.precruving requirements as per the perm yard (sse/p.way/con-i/dmv) is must. attached calculation sheet with tender to be refered to for precurving requirement
Read moreof your Industry type