Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Providing And Fixing The 06 Nos. 3 Pole 33 K V 800 A Dbcr Isolator And 13 Nos. 3 Pole 11 K V 400 A Goab (Double Break Type) And Other Related Work At Rajnagar Ro Substation And Its Associated Power Feeders.
|
| Description |
Providing And Fixing The 06 Nos. 3 Pole 33 K V 800 A Dbcr
Isolator And 13 Nos. 3 Pole 11 K V 400 A Goab (Double Break Type) And Other Related Work At Rajnagar Ro Substation And Its Associated Power Feeders.
|
| Organisation | South Eastern Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2026_SECL_361071_1 |
|
Reference Number |
AGM/HSD/SO(EnM)/E-Tender/18, dt.15.06.2026 |
| Tender Fee | 0 |
| EMD | 11900 |
| Tender Value | - |
| Place | Hasdeo Area |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=373947 |
| Start Date | June 15, 2026 15:30 |
| End Date |
Expired
25/06/2026
Expired 111 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Replacement of faulty protective relays along with complete testing of all protective relays associated with 220 kv and 132 kv feeders (including transformer feeders) and testing of 220 kv and 132 kv circuit breakers at 220/132 kv gss, adp-ii (rcp)
Replacement of faulty protective relays along with complete testing of all protective relays associated with 220 kv and 132 kv feeders (including transformer feeders) and testing of 220 kv and 132 kv circuit breakers at 220/132 kv gss, adp-ii (rcp)
Read moreSpares suitable for siemens make 420 kv,2000amps,tp 415v motor operated centre break isolator with single earth switch type 400 kv hcb installed at 400 kv switchyard
Spares suitable for siemens make 420 kv,2000amps,tp 415v motor operated centre break isolator with single earth switch type 400 kv hcb installed at 400 kv switchyard
Read more(a) erection /dismantling of poles along with conductors and other associated accessories 3.3 kv o/h line (feeder 1, feeder 2 , feeder 3 and feeder 4), and installation of 11 kv grade goab switch, installation of lighting transformer, switch shifting
(a) erection /dismantling of poles along with conductors and other associated accessories 3.3 kv o/h line (feeder 1, feeder 2 , feeder 3 and feeder 4), and installation of 11 kv grade goab switch, installation of lighting transformer, switch shifting
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read more33 kv line isolator 400a 800a 33 kv bus isolator 400a 800a
33 kv line isolator 400a 800a 33 kv bus isolator 400a 800a&#x0d &#x0d
Read more33 kv line isolator 400a/800a 33 kv bus isolator 400a/800a
33 kv line isolator 400a/800a 33 kv bus isolator 400a/800a
Read more33 kv line isolator(400a/800a), 33 kv bus isolator (400a/800a), 11 kv tpmo , 11 kv fuse set, 33 kv fuse set
33 kv line isolator(400a/800a), 33 kv bus isolator (400a/800a), 11 kv tpmo , 11 kv fuse set, 33 kv fuse set
Read more33 kv line isolator(400a/800a), 33 kv bus isolator (400a/800a), 11 kv tpmo and 11 kv fuse set, 33 kv fuse set
33 kv line isolator(400a/800a), 33 kv bus isolator (400a/800a), 11 kv tpmo and 11 kv fuse set, 33 kv fuse set
Read moreRepairing of goab isolator 33kv of different feeders at regional sub station kathara
Repairing of goab isolator 33kv of different feeders at regional sub station kathara
Read moreof your Industry type