Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Emergency Battery Charger Unit, Capacity 10 A, Input Voltage 415 V Ac, 3 Phase, Output 24 V Dc Confirming To Icf Spec. No. Icf/Elec/841, Rev. A Suitable For Garib Rath Type Ac Coaches.
|
| Description |
Emergency Battery Charger Unit, Capacity 10 A, Input Voltage 415 V Ac, 3 Phase, Output 24 V Dc Confirming To Icf Spec. No. Icf/Elec/841, Rev. A Suitable For Garib Rath Type Ac Coaches.
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 15, 2026 20:20 |
| End Date |
Open
05/11/2026
19 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Stripping of da set along with accessories and power panel from garib rath/icf power car .
Stripping of da set along with accessories and power panel from garib rath/icf power car .
Read more24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
Read moreDriver 18 watt for 4 feet light fitting for 3 phase rakes suitable for ensave led light fitting as per rdso spec. no. rdso/pe/spec/tl/0091-2016 (rrv-1). (input voltage- 110v ac/dc,output voltage-24v dc)
Driver 18 watt for 4 feet light fitting for 3 phase rakes suitable for ensave led light fitting as per rdso spec. no. rdso/pe/spec/tl/0091-2016 (rrv-1). (input voltage- 110v ac/dc,output voltage-24v dc)
Read more1. premium unity processor make schneider electric part no.-tsxp573634m,2. pcmcia memory ext. model schneider electric part no. -tsxmrpc002m,3. 220v double slot rack power supply model - schneider electric part no.- tsxpsy5500m,4. 12 slot expandable rack model --schneider electric part no. -tsxrky12ex,5. tcp-ip module model -- schneider electric part no. - tsxety4103,6. 32 channel 24v dc input module model -schneider electric part no. -tsxdey32d2k,7. 32 channel 24v dc output module model -schneider electric part no. -tsxdsy32t2k,8. 8 channel analog input module model -schneider electric part no. -tsxaey810,9. 4 channel rtd input module model -schneider electric part no. -tsxaey414,10. 4 channel analog input module model -schneider electric part no. -tsxasy410,11. prefab cable for analogue input module model - schneider electric part no. -tsxcap030,12. prefab cable for digital input and digital output 5 mtr model - schneider electric part no. - tsxcdp503,13. terminal block model - schneider electric part no. -
1. premium unity processor make schneider electric part no.-tsxp573634m,2. pcmcia memory ext. model schneider electric part no. -tsxmrpc002m,3. 220v double slot rack power supply model - schneider electric part no.- tsxpsy5500m,4. 12 slot expandable rack model --schneider electric part no. -tsxrky12ex,5. tcp-ip module model -- schneider electric part no. - tsxety4103,6. 32 channel 24v dc input module model -schneider electric part no. -tsxdey32d2k,7. 32 channel 24v dc output module model -schneider electric part no. -tsxdsy32t2k,8. 8 channel analog input module model -schneider electric part no. -tsxaey810,9. 4 channel rtd input module model -schneider electric part no. -tsxaey414,10. 4 channel analog input module model -schneider electric part no. -tsxasy410,11. prefab cable for analogue input module model - schneider electric part no. -tsxcap030,12. prefab cable for digital input and digital output 5 mtr model - schneider electric part no. - tsxcdp503,13. terminal block model - schneider electric part no. -
Read moreControl transformer, 200va, 750/415v, type-ii, 50hz, single phase, h class insulation, dry type & air cooled, along with fuses complete, suitable for use in switch board cabinets of eog/hog lhb type ac coaches, powers cars, lhb garib rath ac coaches & smart lhb hog ac coaches, confirming to rdso specification no. rdso/pe/spec/ac/0203/-2020 (rev-0). make as per letter. no. el/7.1.108/sbc/main file dt: 16.04.2021 are bhasin packard, nacei, trolex, ramyaa, trinitron, kontact consortium, abrol o
Control transformer, 200va, 750/415v, type-ii, 50hz, single phase, h class insulation, dry type & air cooled, along with fuses complete, suitable for use in switch board cabinets of eog/hog lhb type ac coaches, powers cars, lhb garib rath ac coaches & smart lhb hog ac coaches, confirming to rdso specification no. rdso/pe/spec/ac/0203/-2020 (rev-0). make as per letter. no. el/7.1.108/sbc/main file dt: 16.04.2021 are bhasin packard, nacei, trolex, ramyaa, trinitron, kontact consortium, abrol o
Read moreGps current interrupter timer, kristron make complete with gps antenna tested ok pair,supply, installation, testing and commissioning of permanent reference electrode zn znso4,dc output voltmeter, digital type,suitable cable glands and accessories,alternating current input digit ammeter,fuse holder complete with slow blow glass fuse for gps timer circuit,filter fuse holder complete with 10a hrc fuse link,psp meter complete with t filter circuitry and associated signal conditioning components oem certified,output voltage control potentiometer, multi turn type,mother board m b kristron 75v 75a tr unit,display board d b kristron 75v 75a tr unit,complete set of controller cards 04 nos controller cards,output fuse holders top and base,mains on indicator,104c controller card,supply of material required for provision of two dedicated earthing stations hp nagar west 1 ohm for la 1 and la 2 cp contractors scope,supply and installation hrc fuse link, 10a filter circuit,filter capacitor,supply of cathode header cable pi
Gps current interrupter timer, kristron make complete with gps antenna tested ok pair,supply, installation, testing and commissioning of permanent reference electrode zn znso4,dc output voltmeter, digital type,suitable cable glands and accessories,alternating current input digit ammeter,fuse holder complete with slow blow glass fuse for gps timer circuit,filter fuse holder complete with 10a hrc fuse link,psp meter complete with t filter circuitry and associated signal conditioning components oem certified,output voltage control potentiometer, multi turn type,mother board m b kristron 75v 75a tr unit,display board d b kristron 75v 75a tr unit,complete set of controller cards 04 nos controller cards,output fuse holders top and base,mains on indicator,104c controller card,supply of material required for provision of two dedicated earthing stations hp nagar west 1 ohm for la 1 and la 2 cp contractors scope,supply and installation hrc fuse link, 10a filter circuit,filter capacitor,supply of cathode header cable pi
Read moreSinumerik tcu 30.2 6fc53120da001aa0, make- siemens,absolute encoder 6fx20015je242dc0,sinamics s120 single motor module input dc 600v output, 3ac 400v, 24a frame size book size c-type internal air cooling. 6sl 3120 1te22 4ac0, make-siemens,as-i power 3a 120v 230v ac as- interface power supply unit, ip20, in 120v 230v ac, out as-i, 3a 30v dc, siemens part-3 rx9501-0ba00, make- siemens,sinumerik pcu 50.5-c electronic control unit 1.8 ghz, 4 gb ram, 24v dc, windows 7 for embedded systems, 6fc 5210 0df52 3aa0 make- siemens
Sinumerik tcu 30.2 6fc53120da001aa0, make- siemens,absolute encoder 6fx20015je242dc0,sinamics s120 single motor module input dc 600v output, 3ac 400v, 24a frame size book size c-type internal air cooling. 6sl 3120 1te22 4ac0, make-siemens,as-i power 3a 120v 230v ac as- interface power supply unit, ip20, in 120v 230v ac, out as-i, 3a 30v dc, siemens part-3 rx9501-0ba00, make- siemens,sinumerik pcu 50.5-c electronic control unit 1.8 ghz, 4 gb ram, 24v dc, windows 7 for embedded systems, 6fc 5210 0df52 3aa0 make- siemens
Read moreEmergency battery charger unit, capacity 10a, input voltage 415v ac, 3 phase, output 24v dc confirming to icf spec. no. icf/elec/841, rev. a suitable for garib rath type ac coaches.
For complete deion and other details, please refer to tender
Read moreEmergency battery charger unit, capacity 10a, input voltage 415v ac, 3 phase, output 24v dc confirming to icf spec. no. icf/elec/841, rev. a suitable for garib rath type ac coaches.
For complete deion and other details, please refer to tender
Read moreEmergency battery charger unit, capacity [emergency battery charger unit, capacity 10a, input voltage 415v ac, 3 phase, output 24v dc confirming to icf spec. no. icf/elec/841, rev. a suitable for garib rath type ac coaches. supplier has to submit prototype approval of icf. ]
For complete deion and other details, please refer to tender
Read moreof your Industry type