Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Tn 33/2024 25/Edc(ch) Replacement Of Bare Conductor By Insulated Covered Conductor (Aaac) In 11 Kv Chalthi Feeder
|
| Description |
Replacement Of Bare Conductor By Insulated Covered Conductor (Aaac) In 11 Kv Chalthi Feeder (Salli To Manch Tamli) Emanating From 33/11 Kv S/S Champawat Under Edd Champawat, Under The Head Of Capital (S.I.)
|
| Organisation | MD - UPCL | State Govt. and UT |
| Tender Id | 2024_UPCL3_75279_1 |
|
Reference Number |
33/2024-25/EDC(CH) |
| Tender Fee | 11800 |
| EMD | 3.5 Lakh |
| Tender Value | - |
| Place | Under EDD UPCL Champawat |
| Link |
View Original Tender Notice
https://uktenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=91814 |
| Start Date | October 12, 2024 22:50 |
| End Date |
Expired
28/10/2024
Expired 718 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Polyimide film covered high conductivity copper conductor annealed bare
Polyimide film covered high conductivity copper conductor annealed bare
Read moreReconductoring using covered conductor for pozhikkara and meenadu feeder under electrical section paravoor
Reconductoring using covered conductor for pozhikkara and meenadu feeder under electrical section paravoor.
Read moreWork for 11 kv bare conductor into covered conductor for simhasth 2028 at various location under city west division ujjain in sstd simhastha 2028 scheme
Work for 11 kv bare conductor into covered conductor for simhasth 2028 at various location under city west division ujjain in sstd simhastha 2028 scheme
Read moreNew covered conductor work nh east side kannetty ,keralafeeds , karunagappally feeder under electrical section karunagapally south.
New covered conductor work nh east side kannetty ,keralafeeds , karunagappally feeder under electrical section karunagapally south.
Read moreWork for 11 kv bare converted into covered conductor for simhasth 2028 at various location city west division ujjain under sstd simhastha 2028 scheme
Work for 11 kv bare converted into covered conductor for simhasth 2028 at various location city west division ujjain under sstd simhastha 2028 scheme
Read moreWork for 11 kv bare conductor to covered conductor in green belt area for reliability of supply during the simhastha under kiosk zone city east division ujjain under sstd simhastha 2028 scheme
Work for 11 kv bare conductor to covered conductor in green belt area for reliability of supply during the simhastha under kiosk zone city east division ujjain under sstd simhastha 2028 scheme
Read moreRe constructing ht covered conductor from panayarakal to madhavassery on dhanuvachapuram 11kv feeder under electrical section, udiyankulangara of electrical division, neyyattinkara under electrical circle, kattakada
Re constructing ht covered conductor from panayarakal to madhavassery on dhanuvachapuram 11kv feeder under electrical section, udiyankulangara of electrical division, neyyattinkara under electrical circle, kattakada
Read moreConversion of bare lt conductor into ab cables and installation of hvds in marshy (dal lake area) of buchwara feeder f03 of 2x10 mva receiving station buchwara under capex budget 2026-27
Conversion of bare lt conductor into ab cables and installation of hvds in marshy (dal lake area) of buchwara feeder f03 of 2x10 mva receiving station buchwara under capex budget 2026-27
Read more4 way rf remote control switch,steel conduit pipe,cable entry plate upto ip 68 rated protection,cable entry frames for preterminated cables upto ip 66 scal,hpmv 150 w lamp with ballast ignitor and ceramic holder,lpmv 150 w lamp with ballast ignitor and ceramic holder,hook up wire,gang capacitor 2 j,oscilator coil,solder wire 250 gm,teak wood board 8 x 10 inch,7-20 pvc cu wire,pvc insulated 2 core wire 1.00 sq mm,3-core v r flexi wire,cts trs flexi wire,cts trs solid conductor wire,weather proof wire,indicator 6 a,kit kat fuse 6 a,electronic sequential controller,ckt 4 channel,electrolytic capacitor,ceramic capacitor 0.1 mfd,preset,scr tyn b04,9 v battery connector,bulb with holder 12 v 6w dc,bulb with holder 12 v 12w dc,bulb with holder 12 v 33 w dc,chart paper different colour,m 6 x 40 mm bolt nut hex,m 8 x 40 mm hex bolt nut,leather leg guard,alumium flux 100 gm,magnetic particle flux 500 gm,thermocoal sheet,khilli 17-1 inch,hard drawn bare aluminium wire,aluminium binding wire,bare aluminium single core 4
4 way rf remote control switch,steel conduit pipe,cable entry plate upto ip 68 rated protection,cable entry frames for preterminated cables upto ip 66 scal,hpmv 150 w lamp with ballast ignitor and ceramic holder,lpmv 150 w lamp with ballast ignitor and ceramic holder,hook up wire,gang capacitor 2 j,oscilator coil,solder wire 250 gm,teak wood board 8 x 10 inch,7-20 pvc cu wire,pvc insulated 2 core wire 1.00 sq mm,3-core v r flexi wire,cts trs flexi wire,cts trs solid conductor wire,weather proof wire,indicator 6 a,kit kat fuse 6 a,electronic sequential controller,ckt 4 channel,electrolytic capacitor,ceramic capacitor 0.1 mfd,preset,scr tyn b04,9 v battery connector,bulb with holder 12 v 6w dc,bulb with holder 12 v 12w dc,bulb with holder 12 v 33 w dc,chart paper different colour,m 6 x 40 mm bolt nut hex,m 8 x 40 mm hex bolt nut,leather leg guard,alumium flux 100 gm,magnetic particle flux 500 gm,thermocoal sheet,khilli 17-1 inch,hard drawn bare aluminium wire,aluminium binding wire,bare aluminium single core 4
Read morePvc insulated single core unsheathed industrial multistrand cables 1 sq mm flame retardant fr conforming to is 694 1990 with bright annealed electrolytic bare copper conductor,porcelain insulating hangers as per approved sample,pvc casing capping 32 mm wide comma not less than 2 mm thick,pvc switch board 7 inch x 4 inch conform to is 14772,pvc switch board 4 inch x 4 inch conform to is 14772,pvc gang box 1 way comma heavy duty,mcb 6 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 6 a dp 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 10 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 10 a dp 240 volt conform to ec 60898 2002 and is 8828 1996,mcb 16 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 16 a dp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 20 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 20 a dp 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 32 a sp conform to iec 60898 2002 and is 8828 1996
Pvc insulated single core unsheathed industrial multistrand cables 1 sq mm flame retardant fr conforming to is 694 1990 with bright annealed electrolytic bare copper conductor,porcelain insulating hangers as per approved sample,pvc casing capping 32 mm wide comma not less than 2 mm thick,pvc switch board 7 inch x 4 inch conform to is 14772,pvc switch board 4 inch x 4 inch conform to is 14772,pvc gang box 1 way comma heavy duty,mcb 6 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 6 a dp 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 10 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 10 a dp 240 volt conform to ec 60898 2002 and is 8828 1996,mcb 16 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 16 a dp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 20 a sp comma 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 20 a dp 240 volt conform to iec 60898 2002 and is 8828 1996,mcb 32 a sp conform to iec 60898 2002 and is 8828 1996
Read moreof your Industry type