Tender Details
Particulars | Details |
---|---|
Title |
Insulation Monitoring Relay (Imr) To Monitor 3 Phase Power Supply Of Voltage Range 110 V Ac, Measuring Range 1 100 K Ohm, Control Voltage 24 240 V Ac / Dc Output 1 C / 0 (Spdt) Contact System Leakage Capacitance 10 Micro Farad As Per Contel Model No. Ir 140 Y 4, Ri R 22
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106503279 |
Reference Number |
51245756A |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Chennai |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/112024/106503279/viewNitPdf_4749090.pdf |
Start Date | October 21, 2024 20:30 |
End Date |
06/11/2024 ( Expired 167 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Led driver, input watt 18 w, voltage 110 v ac/dc, voltage range 90-140 vac/dc, rated output voltage: 24 v, suitable for 18w,type-l light fitting for lhb ac coaches . as per rdso spec rdso/pe/spec/tl/0091-2016 (rev.1).
For complete deion and other details, please refer to tender
Read moreLed driver rated input watt 9w, 110 v ac/ dc, operating range 90-140 v ac /dc, rated output watt 8w, rated output voltage 24v confirming to rdso specification rdso/pe/spec/tl/0091-2016 rev 01, suitable for led light b & c fitting of lhb coaches. make intra industries, integ electronics, dr auto industries, rt vision technologies or as per approved vendor list.
For complete deion and other details, please refer to tender
Read morePower contactor 110 amp. 4 pole 415 v ac [power contactor 110 amp. 4 pole 415 v ac coil voltage 380-415 v ac 50 hz with 2 nc aux contact along with surge suppresor as per s.no.59 & item no. k-08, place of installation s1k43 of bill of material of rdso spec no. rdso/pe/spec/ac/0184-2015(rev.0). brands: l&t/siemens/schneider/abb only 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for acceptance
For complete deion and other details, please refer to tender
Read moreVoltage phase control (mmr-measuring mon [voltage phase control (mmr-measuring monitoring relay) net 1&2, 3 ac, 1000 v aux. voltage 110 v ac/dc confirming to rdso/pe spec/ac/o184-2015 (rev 1) and as per rdso letter no el/7.1.108/mssbc/17.09.21 sr. no. 14 item. make: m/s dold cat no-bd9080 12/003 or equivalent m/s. carlo gavazzi cat no. dpco1dm1kb001 or m/s abb no. cm-mpn.72s or m/s. l&t-gic no. smb110 or m/s. phoenix only. (to be supplied with oem s proof of purchase along with test certificat
For complete deion and other details, please refer to tender
Read moreInsulation control 110 v ac measuring range 1-100 k ohm control voltage 24-240 v ac/dc output 1c/0(spdt) contact system leakage capacitance 10 micro farad
For complete deion and other details, please refer to tender
Read moreInsulation monitoring relay( insulation control 415 ac), rated voltage 0 to 500 ac, control voltage 24-240v ac/dc for lhb ac coaches. makes: contrel (ir 470ly-21a, ri-r138), abb (cm.iws.2s) , schneider (vigil ohm/imd-im10), siemens (3ug4581 - 1aw30), dold (il 5880) or similar of waka or bender make as per bill of material (bom) of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev.1) as per drg.no. nil specn: nil
For complete deion and other details, please refer to tender
Read moreInsulation monitoring relay. (imr) to monitor 3 phase power supply of voltage range 110volt ac , measuring range 1-100 k ohm, contrel voltage 24-240 volt ac /dc output ic/0 (spdt)contact system leakage capacitance 10 micro farad as per control model no ir 140y-4,ri- r 22(or)abb model no cm. iws.is (or)schneider model no vigil ohm/im10 (or) siemens model no 3ug4581-1aw30 (or) dold model no il5880 (or)bender (or) woka. suitable for installation in s1a6 as per rdso /pe/spec/ac/0184-2015 (rev 1)
For complete deion and other details, please refer to tender
Read moreInsulation monitoring relay, 415v ac, 3 phase, neutral isolated, voltage range 0-500 v ac, insulation measuring range-10 k ohm to 150 k ohm, control voltage: 24-240 v ac/dc, place of installation s1a7, of bill of material of rdso spec. no. rdso/pe/ spec/ ac/0184-2015(rev.1), used for insulation control 415 v of lhb type ac coaches, confirming to rdso spec. no.rdso/pe/spec/ac-0184-2015 (rev.1), suitable for lhb type ac coaches switch boardcabinet (s1a07) or latest. make -control, abb, schneider
For complete deion and other details, please refer to tender
Read moreMeasuring monitoring relay (lt mmr). vol [measuring monitoring relay (lt mmr). voltage phase control 400/480 v ac /- 15 percent , 50-60 hz, control 300-500 v ac, suitable to be installed in sbc of lhb type eog ac coaches., conforming to rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) brands: abb, carlo gavazi, siemens, schnieder, dold note: 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for
For complete deion and other details, please refer to tender
Read morePower contactor 110 amp. 4 pole 415 v ac [power contactor 110 amp. 4 pole 415 v ac coil voltage 380-415 v ac 50 hz with 2 nc aux contact along with surge suppresor as per s.no.59 & item no. k-08, place of installation s1k43 of bill of material of rdso spec no. rdso/pe/spec/ac/0184-2015(rev.0). brands: l&t/siemens/schneider/abb only 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for acceptance
For complete deion and other details, please refer to tender
Read moreof your Industry type