Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Maintenance And Reconditioning Of 01 No 10 Mva 33 Kv/11 Kv And 1 No 10 Mva 33 Kv/6.6 Kv Power Transformers Installed At Central Sub Station Basantpur Under Hazaribagh Area
|
| Description |
Maintenance And Reconditioning Of 01 No 10 Mva 33 Kv/11 Kv And 1 No 10 Mva 33 Kv/6.6 Kv Power Transformers Installed At Central Sub Station Basantpur Under Hazaribagh Area
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_CCL_309489_1 |
|
Reference Number |
GM(H)/EnM/Tender/24-25/03 |
| Tender Fee | 0 |
| EMD | 9700 |
| Tender Value | |
| Place | Substation Basantpur |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=320671 |
| Start Date | June 01, 2024 16:30 |
| End Date |
Expired
11/06/2024
Expired 776 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Provision of arboriculture and associated work at certain location at af station arjan singh under ge p af panagarh
Provision of arboriculture and associated work at certain location at af station arjan singh under ge p af panagarh
Read moreMaintenance and reconditioning of 1250a 33kv mocb of allind make installed for primary control of 10mva 33kv/6.6kv transformer at central sub-station basantpur under hazaribagh area
Maintenance and reconditioning of 1250a 33kv mocb of allind make installed for primary control of 10mva 33kv/6.6kv transformer at central sub-station basantpur under hazaribagh area
Read moreMaintenance and reconditioning of 1250amp, 33kv sf6 breaker voltas make at site central sub-station basantpur under hazaribagh area
Maintenance and reconditioning of 1250amp, 33kv sf6 breaker voltas make at site central sub-station basantpur under hazaribagh area
Read moreRewinding and repairing of 160kva 33kv/433v truevolt make sl. no. 569/1 installed at central sub-station basantpur under hazaribagh area
Rewinding and repairing of 160kva 33kv/433v truevolt make sl. no. 569/1 installed at central sub-station basantpur under hazaribagh area
Read moreRepairing, maintenance and installation of differential protection relay system in 10 mva, 33kv/11kv, power transformer at main substation 33kv/11kv/3.3kv of peocp under hazaribagh area.
Repairing, maintenance and installation of differential protection relay system in 10 mva, 33kv/11kv, power transformer at main substation 33kv/11kv/3.3kv of peocp under hazaribagh area.
Read moreMaintenance and oil filtration of 02 no. of 33kv/11kv, 10 mva power transformer installed at murpa substation under kuju area.
Maintenance and oil filtration of 02 no. of 33kv/11kv, 10 mva power transformer installed at murpa substation under kuju area.
Read moreRepairing /reconditioning and de-sluging work of 03 nos. power transformer 10 mva, 33kv/6.6kv of eastern and coal sub-station nigahi project
Repairing /reconditioning and de-sluging work of 03 nos. power transformer 10 mva, 33kv/6.6kv of eastern and coal sub-station nigahi project
Read moreRepairing/ reconditioning of 02 no, sf6 breaker ,33kv, 1250a make abb power controlling to 33kv feeder and primary control of 12.5 mva, 33kv/6.6kv transformers installed at 2 x 12.5 mva 33kv/6.6 kv main substation, rp
Repairing/ reconditioning of 02 no, sf6 breaker ,33kv, 1250a make abb power controlling to 33kv feeder and primary control of 12.5 mva, 33kv/6.6kv transformers installed at 2 x 12.5 mva 33kv/6.6 kv main substation, rp
Read moreRepairing and maintenance of 1250 amp 33kv grade sf6 make voltas of 10mva 33kv/11kv power transformer at main sub-station of peocp under hazaribagh area
Repairing and maintenance of 1250 amp 33kv grade sf6 make voltas of 10mva 33kv/11kv power transformer at main sub-station of peocp under hazaribagh area
Read moreRepairing and reconditioning of protective device of (a) 2 mva power transformer, volts-11kv/3.3kv, 04-no. colony feeder (b) 1 mva 11kv/3.3kv cpp feeder (c) 3mva, 33kv/11kv staff feeder and (d) 3mva 33kv/11kv ktc feeder installed at regional sub-stat
Repairing and reconditioning of protective device of (a) 2 mva power transformer, volts-11kv/3.3kv, 04-no. colony feeder (b) 1 mva 11kv/3.3kv cpp feeder (c) 3mva, 33kv/11kv staff feeder and (d) 3mva 33kv/11kv ktc feeder installed at regional sub-stat
Read moreof your Industry type