| Particulars | Details |
|---|---|
| Title |
Providing And Replacement Of Worn Out Components Of 100 Kva Manual Voltage Stabilizer Of T/Well 28 Gangyal And 100 Kva Manual Voltage Stabilizer Of T/Well Model Town Under Non Plan
|
| Description |
Providing And Replacement Of Worn Out Components Of 100 Kva Manual Voltage Stabilizer Of T/Well 28 Gangyal And 100 Kva Manual Voltage Stabilizer Of T/Well Model Town Under Non Plan
|
| Organisation | PHE | State Govt. and UT |
| Tender Id | 2025_PHE_270968_1 |
|
Reference Number |
PHEJ/MS/89 of 2024-25 Dated 23-01-2025 |
| Tender Fee | 200 |
| EMD | 0 |
| Tender Value | - |
| Place | Jammu |
| Link |
View Original Tender Notice
https://jktenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=837587 |
| Start Date | January 25, 2025 15:30 |
| End Date |
Expired
31/01/2025
Expired 625 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Servo controlled voltage stabilizer of rating 150 kva as per annexure a.
Servo controlled voltage stabilizer of rating 150 kva as per annexure a.
Read moreSitc of 15 kva servo voltage stabilizer along with allied works at dc office udhampur
Sitc of 15 kva servo voltage stabilizer along with allied works at dc office udhampur
Read moreVariac 200 amp for 400 kva oil cool servo voltage stabilizer make-neelkanth power solutions
Variac 200 amp for 400 kva oil cool servo voltage stabilizer make-neelkanth power solutions
Read more2 ton split air conditioner,voltage stabilizer 5 kva for 2 ton ac,outdoor unit stand,copper pipe,installation charge
2 ton split air conditioner,voltage stabilizer 5 kva for 2 ton ac,outdoor unit stand,copper pipe,installation charge
Read moreContactor for net 1 & 2 rated voltage: 1 [contactor for net 1 & 2 rated voltage: 1000 v a. c, rated kva- 100 at rated voltage & 70 .
Contactor for net 1 & 2 rated voltage: 1 [contactor for net 1 & 2 rated voltage: 1000 v a. c, rated kva- 100 at rated voltage & 70 .
Read moreSitc of 100 kva dg set, supply and laying of power cable, supply and fabrication of manual screen bar etc. work at h.c. ghat sps, varanasi
Sitc of 100 kva dg set, supply and laying of power cable, supply and fabrication of manual screen bar etc. work at h.c. ghat sps, varanasi
Read moreWindow ac 1.5 ton,4 kva voltage stabilizer,heavy duty ms iron bracket,32 amp ac socket with plug,32 amp 2 pole mcb,2.5 sq mm copper wire,nut bolt clamps welding items and beeding
Window ac 1.5 ton,4 kva voltage stabilizer,heavy duty ms iron bracket,32 amp ac socket with plug,32 amp 2 pole mcb,2.5 sq mm copper wire,nut bolt clamps welding items and beeding
Read moreAir cooled servo controlled voltage stabilizer 30 kva to 3 phase,nabhayan pro 2.0 screen remote 50 of fly time with 4 batteries,eachine ev800 fpv goggle,radio master pocket rc elrs,printing of register as per sample
Air cooled servo controlled voltage stabilizer 30 kva to 3 phase,nabhayan pro 2.0 screen remote 50 of fly time with 4 batteries,eachine ev800 fpv goggle,radio master pocket rc elrs,printing of register as per sample
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Read moreTaking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span
Taking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span
Read moreof your Industry type