Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Air Circuit Breaker (Acb) Suitable For Lhb Power Car Of System Voltage 750 V, Capacity 800 Amp, Breaking Capacity 50 Ka, Frequency 50 Hz, 3 Pole Mf (With Inbuilt Uv Protection, Thermal, Magnetic Release), 6 No + 6 Nc Aux Contact Block And Draw Out Acbs Terminal Adaptors) Similar To L&T Make Acb Type: Cn Cs 800 C Conforming To Rcf Specification No: Edts 103, Rev D, Am 07 Or Latest, Make Lauritz Knudsen Formerly L&T/Abb/Ge Only.
|
| Description |
Air Circuit Breaker (Acb) Suitable For Lhb Power Car Of System Voltage 750 V, Capacity 800 Amp, Breaking Capacity 50 Ka, Frequency 50 Hz, 3 Pole Mf (With Inbuilt Uv Protection, Thermal, Magnetic Release), 6 No + 6 Nc Aux Contact Block And Draw Out Acbs Terminal Adaptors) Similar To L&T Make Acb Type: Cn Cs 800 C Conforming To Rcf Specification No: Edts 103, Rev D, Am 07 Or Latest, Make Lauritz Knudsen Formerly L&T/Abb/Ge Only.
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 06, 2026 15:51 |
| End Date |
Open
09/11/2026
24 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
C&s make acb 2500a 415v 3p, ah-25d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 50ka icw(1s) : 50ka,c&s make acb 3200a 415v 3p, ah-30d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 65ka icw(1s) : 65ka,c&s air circuit breaker ah 40d cs, in: 4000a, ue 415 v breaking capacity at 415 v, icu 100ka, ics 1
C&s make acb 2500a 415v 3p, ah-25d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 50ka icw(1s) : 50ka,c&s make acb 3200a 415v 3p, ah-30d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 65ka icw(1s) : 65ka,c&s air circuit breaker ah 40d cs, in: 4000a, ue 415 v breaking capacity at 415 v, icu 100ka, ics 1
Read moreAcb, 800a, 3p, 50ka, mm: cn-cs 800s1,acb, 415v ac, 1000a, 50ka, mm: cn-cs 1000c,acb, 415v, 2000a, 3
Read more
Acb, 800a, 3p, 50ka, mm: cn-cs 800s1,acb, 415v ac, 1000a, 50ka, mm: cn-cs 1000c,acb, 415v, 2000a, 3
Read more
Supply , installation and commissioning of air circuit breaker(acb) suitable for lhb power car of system voltage-750 v , capacity-800 amp , breaking capacity - 50ka , frequency- 50 hz, 3 pole mf( with inbuilt uv protection , thermal , magnetic release, 6 no 6 nc aux contact block and draw-out acbs terminal adaptors) along with 03 nos. suitable size of ct s. similar to l&t make acb type : cn-cs 800c conforming to rcf specification no : edts 103 , rev-d, am-07 or latest, l&t make for suitab
For complete deion and other details, please refer to tender
Read moreUnder voltage release (uvr) type-mv, coil voltage 240 v ac cat no. sl92720b000, suitable for l&t make acb model no. cn-cs-800c confirming to edts 103, rev-d, am-7
For complete deion and other details, please refer to tender
Read moreAir circuit breaker(acb) for dg set application of system , voltage-750 v , capacity-800 amp , breaking capacity - 50ka , frequency- 50 hz, 3 pole mf( with inbuilt uv protection , thermal , magnetic release and 6 no 6 nc aux contact block) similar to l&t make acb type : cn-cs 800c conforming to rcf specification no : edts 103 , rev-d , am-07 or latest, make- l&t, abb or equivalent in all respect. note: material should be supplied by oem or their authorized dealers only.
For complete deion and other details, please refer to tender
Read moreAir circuit breaker 3 pole, 800 amp, 750v, 50hz cn-cs-800c with 6 no 6nc open air execution thermal magnetic mv voltage release dni fixed type manually operated. make: l&t (model no. cn-cs-800c)/ abb, or any rdso approved vender with latest amendment. confirming to rcf specification no. edts 103 rev-d, amnd-7, suitable for rajdhani/ shatabdi lhb power cars (swr pl no. 45144898).
For complete deion and other details, please refer to tender
Read moreAir circuit breaker cn-cs 800c, 3x750v, 800a, 6 no6 nc ct for 240......300 amps, dn 1e voltage release mv, earth fault release with 30 percent /40 percent /50 percent to abb cat no-e2n800 or ge cat no- rms- 9d or l&t cat no. cncs 800c only as per rcf spec no. edts 103, rev-d, amd-4.
For complete deion and other details, please refer to tender
Read moreUnder voltage relay (uvr) type-mv, coil voltage: 240v ac. cat. no. sl92720b000 , suitable for l&t make acb model no. cn-cs-800c. make: l&t. note: oem( m/s l&t) or their authorized dealers with tender specific authorization letters from oem only to quote with documentary evidence
For complete deion and other details, please refer to tender
Read moreof your Industry type