| Particulars | Details |
|---|---|
| Title |
Invitation To Pre Tender Meet For Ups System Batteries Vrla Lead Acid For Vbpl Project Of Bpcl
|
| Description |
Invitation To Pre Tender Meet For Ups System Batteries Vrla Lead Acid For Vbpl Project Of Bpcl
|
| Organisation | Engineers India Limited,MoPNG | Central Govt. Ministry/Department |
| Tender Id | 2025_EIL_869133_1 |
|
Reference Number |
Invitation to Pre-Tender meet for UPS System, Batteries-Lead Acid (VRLA) for VBPL Project of BPCL |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | As per the invitation document |
| Link |
View Original Tender Notice
https://eprocure.gov.in/eprocure/app?page=FrontEndTenderDetailsExternal&service=page&tnid=913774 |
| Start Date | July 16, 2025 23:40 |
| End Date |
Expired
21/07/2025
Expired 448 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Invitation to pre-tender meet for 66kv switchyard for vbpl project of bpcl
Invitation to pre-tender meet for 66kv switchyard for vbpl project of bpcl
Read moreInvitation to pre-tender meet for filter-basket for vbpl project of bpcl
As per the invitation document
Read moreInvitation to pre-tender meet for mainline ball valves for vbpl project of bpcl
Invitation to pre-tender meet for mainline ball valves for vbpl project of bpcl
Read moreLead acid batteries (vrla type) of 700ah capacity
1)lead acid batteries (vrla type) of 700ah capacity each for the 110v dc system for power house as per annexure c scope of supply sl. no. 1 of technical specifcation no.hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073005). qty: 2 st 2)110v dc float cum boost chargers (150 a) with adequat rating for 700 ah vrla battery 110 v dc system as per annexure c scope of supply sl. no. 2 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073005). qty: 2 st 3)110v main dcdb for power house (sectionalized dc distribution board of 110v at power house - near control room) as per annexure c scope of supply sl. no. 3 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073005). qty: 1 st 4)2 nos. 5kva inverters (fed from 230v ac main dcdb in power house control room) and 1 no. acdb complete with all accessories as per annexure c scope of supply sl. no. 4 of technical specifcation no. hpe/rhg/dcsys/ps/01. qty: 2 st 5)lead acid battery (vrla type) of 100 ah capacity each for the 110v dc system for dam as per annexure c scope of supply sl. no. 5 of technical specifcation no.hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073006). qty: 1 st 6)110v dc float cum boost chargers with adequate ratingfor 110 v dc system 100 ah battery for dam as per annexure c scope of supply sl. no. 6 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073006). qty: 1 st 7)110v dcdb at dam site as per annexure c scope of supplysl. no. 7 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073006). qty: 1 st 8)lead acid battery (vrla type) of 50 ah capacity each for the 48v dc system for bf valve house as per annexure c scope of supply sl. no. 8 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073007). qty: 1 st 9)110v dc float cum boost chargers with adequate rating for 48 v 50 ah battery dc system as per annexure c scope of supply sl. no. 9 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073007). qty: 1 st 10)48v dcdb at bf valve house as per annexure c scope of supply sl. no. 10 of technical specifcation no.hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073007). qty: 1 st
Read moreLead acid batteries (vrla type) of 700ah capacity
1)lead acid batteries (vrla type) of 700ah capacity each for the 110v dc system for power house as per annexure c scope of supply sl. no. 1 of technical specifcation no.hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073005). qty: 2 st 2)110v dc float cum boost chargers (150 a) with adequat rating for 700 ah vrla battery 110 v dc system as per annexure c scope of supply sl. no. 2 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073005). qty: 2 st 3)110v main dcdb for power house (sectionalized dc distribution board of 110v at power house - near control room) as per annexure c scope of supply sl. no. 3 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073005). qty: 1 st 4)2 nos. 5kva inverters (fed from 230v ac main dcdb in power house control room) and 1 no. acdb complete with all accessories as per annexure c scope of supply sl. no. 4 of technical specifcation no. hpe/rhg/dcsys/ps/01. qty: 2 st 5)lead acid battery (vrla type) of 100 ah capacity each for the 110v dc system for dam as per annexure c scope of supply sl. no. 5 of technical specifcation no.hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073006). qty: 1 st 6)110v dc float cum boost chargers with adequate ratingfor 110 v dc system 100 ah battery for dam as per annexure c scope of supply sl. no. 6 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073006). qty: 1 st 7)110v dcdb at dam site as per annexure c scope of supplysl. no. 7 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073006). qty: 1 st 8)lead acid battery (vrla type) of 50 ah capacity each for the 48v dc system for bf valve house as per annexure c scope of supply sl. no. 8 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073007). qty: 1 st 9)110v dc float cum boost chargers with adequate rating for 48 v 50 ah battery dc system as per annexure c scope of supply sl. no. 9 of technical specifcation no. hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073007). qty: 1 st 10)48v dcdb at bf valve house as per annexure c scope of supply sl. no. 10 of technical specifcation no.hpe/rhg/dcsys/ps/01. (refer bhel sld 12900073007). qty: 1 st
Read moreInvitation to pre-tender meeting for plug valves for vbpl project of m/s bpcl
Invitation to pre-tender meeting for plug valves for vbpl project of m/s bpcl